1 10/100/1000TX A me 1 1000X SFP Slot |Mea hoʻololi pāʻoihana ʻoihana liʻiliʻi JHA-IGS11C

ʻO ka wehewehe pōkole:

Kākoʻo iā 1 1000Base-X SFP slot a me 1 10/100/1000Base-T(X) awa Ethernet.
Hoʻolālā ʻia e hoʻokomo i loko o ka paʻi kiʻi kiʻi palena palena, hiki ke hoʻohana ʻia e like me Din-Rail i kau ʻia a i ʻole ʻāpana i kau ʻia i ka panel.
Kākoʻo i ka Link Fault Pass Through (LFP), ke ʻano hoʻololi a me ke ʻano hoʻololi.
DC10-55V mana redundancy.
IP40 Rated Alu


Nānā nui

Hoʻoiho

2-puka ʻOihana Media Mea hoʻololi, me 1 1000Base-X SFP Slot a me 1 10/100/1000Base-T(X) ʻAwa Ethernet

IGS11C

ʻO HA-IGS11C kahi mea hoʻololi pāpaʻi liʻiliʻi liʻiliʻi maoli, ua hoʻolālā ʻia no kahi paʻa kiʻi paʻi koʻikoʻi akā palena ʻole.Hiki ke hoʻohana ʻia e ka laulā o VDC a i ʻole DC mana adapter waho, mana hoʻokomo (DC10-55V).Me kāna hoʻolālā multi-purpose, hiki ke hoʻohana ʻia no Din-Rail a i ʻole i kau ʻia i ka paia.He ʻāpana kūpono ia no ka nānā ʻana i ka IP, ka nānā ʻana i ke kaʻa a me ka noi palekana i ka ʻāina koʻikoʻi.

Kākoʻo ʻo JHA-IGS11C i ka pahu 1-port 1000Base-X SFP a me 1 awa 10/100/1000Base-T(X).Kākoʻo ia i ka CE, FCC, RoHS maʻamau, ka pahu metala ikaika ikaika.Kākoʻo ke kuapo iā IEEE802.3, IEEE802.3u, IEEE802.3x me 10/100Base-T(X).ʻO ka -40-85 ℃ hiki ke hoʻokō i nā ʻano o ka ʻenehana ʻenehana, e hāʻawi ana i ka hopena hilinaʻi a me ka hoʻokele waiwai no kāu ʻoihana Ethernet ʻoihana.

Kūlana Kūlana IEEE802.3, IEEE802.3u, IEEE802.3x

Mana Kahe

IEEE802.3x kahe kahe, hoʻi kaomi kahe mana

ʻAno hoʻololi

Ka helu hoʻouna: 0.446MppsKe ʻano hoʻoili: hale kūʻai a i muaKa nui o ka pahu pahu: 1MPūnaehana hoʻololi Bandwidth: 0.6Gbps

Ka nui papaʻaina MAC: 1K

Manawa Hoʻopaneʻe: <3μs

Awa Ethernet

10/100/1000Base-T(X) kaohi kaʻa kaʻa, Hapa/piha duplex a me MDI/MDI-X ʻike ʻakomi

Awa Uila

1000Base-X SFP slot

Hōʻike LED

Hōʻike Mana: PWRHōʻailona Port Fiber: SDHōʻailona hōʻailona Fiber: LK / ACT

Hoʻololi DIP

1.Jumbo Puke2. Hoʻopili i ka hala hewa (LFP)

Lako ikehu

Voltage Komo: DC10-55VMea hoʻohui: 3 bit 5.08mm Poka pahu hoʻoneʻeHaawe piha: <2WMechanism Protection: Overload Protection / Reverse Connection Protection / Redundancy Protection

Hoʻolālā Mechanical

Shell: IP40 pale, Aluminum-alloy shell

Ana: 59*36*49mm(L*W*H)

Kaumaha: 150g

Hoʻokomo: DIN-rail kau ʻana, kau ʻana i ka paia

Kaiapuni Hana

Ka Mahana Hana: -40 a 85°C

Ka Mahana Waihona: -40 a 85°C

ʻO ka haʻahaʻa haʻahaʻa pili ʻana: 5% a 95% (ka hoʻopaʻa ʻole)

Nā Kūlana ʻOihana

EMI:FCC Māhele 15 Māhele B Papa A, EN 55022 Papa A

EMS:EN61000-4-2 (ESD), Papa 4 ma 15kV(Ea), 8kV(Hoʻokaʻaʻike)

EN61000-4-3 (R/S), Papa 3 ma 10V/m

EN61000-4-4 (EFT), Papa 4 ma 4kV(Power Port), 2kV(Date Port)

EN61000-4-5 (Surge), Papa 4 ma 4kV

EN61000-4-6 (CS), Papa 3 ma 10V/m

EN61000-4-8, Papa 5 ma 100A/m

Haʻalulu:IEC 60068-2-27

Hāʻule manuahi: IEC 60068-2-32

Kuʻi: IEC 60068-2-6

Palapala hōʻoia

CE, FCC, RoHS

MTBF

> 100,000 hola

Palapala hōʻoia

5-makahiki

 

 

 

Hōʻike No.

ʻO ka wehewehe ʻana o ka waiwai

JHA-IFS11C

Mea hoʻololi Media ʻOihana, 1*100Base-X SFP Slot + 1*10/100Base-T(X) RJ45 Port, DIN-Rail, DC10-55V

JHA-IF11C

Mea hoʻololi ʻenehana ʻenehana, 1*100Base-FX Fiber Port + 1*10/100Base-T(X) RJ45 Port, SC, Multimode, Pālua Fiber, 2Km, DIN-Rail, DC10-55V

JHA-IF11C-20

Mea hoʻololi Media ʻOihana, 1*100Base-FX Fiber Port + 1*10/100Base-T(X) RJ45 Port, SC, Hoʻokahi Manaʻo, Pālua Fiber, 20Km, DIN-Rail, DC10-55V

JHA-IF11CW-20

Mea hoʻololi Media ʻOihana, 1*100Base-FX Fiber Port + 1*10/100Base-T(X) RJ45 Port, SC, Single Mode, Single Fiber, 20Km, DIN-Rail, DC10-55V

JHA-IGS11C

Mea hoʻololi Media ʻOihana, 1*1000Base-X SFP Slot + 1*100/1000Base-T(X) RJ45 Port, DIN-Rail, DC10-55V

JHA-IG11C

Mea hoʻololi Media ʻOihana, 1*1000Base-FX Fiber Port + 1*100/1000Base-T(X) RJ45 Port, SC, Multimode, Pālua Uila, 2Km, DIN-Rail,DC10-55V

JHA-IG11C-20

Mea hoʻololi Media ʻOihana, 1*1000Base-FX Fiber Port + 1*100/1000Base-T(X) RJ45 Port, SC, Hoʻokahi Manaʻo, Pālua Fiber, 20Km, DIN-Rail, DC10-55V


  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou