- Pang-industriyang Ethernet Switch
- Fiber Media Converter
- Fiber Ethernet Switch
- Power Over Ethernet
- SFP Module
- AOC/DAC Cable
- Fiber Ethernet Server Adapter
- Fiber Video Converter
- Converter ng Interface
- PDH-SDH Multiplexer
- Telepono Fiber Video Converter
- FTTH
- Mga Rack at Enclosure
- HDMI/VGA Extender
- HDMI Splitter
- WDM
- OTN/WDM Optical Transmission Network System
0102030405

01
Magandang Kalidad FTTH - 4*10/100/1000M Ethernet interface+1 EPON interface EPON ONU JHA700-E104GP-BR520 - JHA
2016-01-08
Maikling Pananaw Ang JHA700-E104GP-BR520 series ay C-Data para sa broadband access market batay sa pagpapakilala ng teknolohiyang EPON passive optical network terminal na mga produkto. Ito ay may EPON OLT ay ginagamit nang magkasama upang magbigay ng kumpletong solusyon sa pag-access ng broadband. Ang teknolohiya ng EPON ay isang uri ng umuusbong na teknolohiya na sinasamantala ang teknolohiya ng PON at ang teknolohiya ng Ethernet ay isa ring uri ng teknolohiya ng point to multi-point network. OLT sa pamamagitan ng passive optical network upang ikonekta ang maramihang ONU na may solong hibla bidirectional teknikal ay maaaring bihirang gumamit ng mga mapagkukunan ng hibla upang matugunan ang mga operator ng multi-user na kinakailangan sa pag-access. Ang serye ng JHA700-E104GP-BR520 ay ganap na nakakatugon sa IEE802.3ah at CTC3.0 na karaniwang protocol. Mayroon itong magandang third-party compatibility para magtrabaho kasama ang third party na OLT, Sinusuportahan nito ang 1Gbps transmission rate pataas at pababa at nagbibigay sa mga user ng mahusay na QOS, flexible bandwidth allocation ng Ethernet services at IP integrated service. Functional Feature ♦ Suportahan ang port-based na limitasyon sa rate at kontrol ng bandwidth; ♦ Alinsunod sa IEEE802.3ah Standard ♦ Hanggang 20KM transmission Distansya ♦ Suportahan ang data encryption, group broadcasting, port Vlan separation, atbp. ♦ Suportahan ang Dynamic Bandwidth Allocation (DBA) ♦ Suportahan ang ONU auto-discovery/Link detection/remote upgrade ng software; ♦ Suportahan ang port mode ng VLAN configuration ♦ Suportahan ang power-off na alarm function, madali para sa link na pagtuklas ng problema ♦ Suportahan ang broadcasting storm resistance function ♦ Suportahan ang port isolation sa pagitan ng iba't ibang port ♦ Suportahan ang port flow control ♦ Suportahan ang ACL at SNMP para i-configure ang data packet filter flexibly ♦ Espesyal na disenyo para sa pag-iwas sa pagkasira ng system upang mapanatili ang matatag na sistema ♦ Suportahan ang software online na pag-upgrade ♦ Pamamahala ng network ng EMS batay sa SNMP, maginhawa para sa pagpapanatili Interface ng produkto at mga kahulugan ng LED Paglalarawan Indicator 1 PWR Power status On: Ang ONU ay power on; Off: Ang ONU ay Power off; 2 PON ONU Register On: Tagumpay sa pagrehistro sa OLTBlinking: Sa proseso ng pagrehistro sa OLT; Off: Sa proseso ng pagrehistro sa OLT; 3 LOS EPON optical signal Naka-on: Optical power na mas mababa kaysa sa sensitivity ng receiver ;Off: Optical sa normal 4 LAN1-4 LAN Port status Naka-on: Ethernet connection ay normal;Blinking: Ang data ay ipinapadala sa pamamagitan ng Ethernet port;Off: Ethernet connection is not set up; Pagtutukoy Item Parameter PON Interface 1 EPON optical interface Matugunan ang 1000BASE-PX20+ standard Symmetric 1.25Gbps upstream/downstream SC/UPC single-mode fiber split ratio: 1:64 Transmission distance 20KM User Ethernet Interface 4*10/100/1000M auto-negotiationFull half duplex mode RJ45 connector Auto MDI/MDI-X 100m distance Power Interface Isang external na 12V 0.5A/DC power supply adapter PONOpticalParameter Wavelength: Tx 1310nm, Rx1490nm Tx Optical Power: 0~4dBm Rx Sensitivity: -27dBm Saturation Optical Power Through: -3dBm Optical Data Transmission: -3dBm Downstream 980Mbps; Upstream 950Mbps Ethernet: 1000Mbps Packet Loss Ratio:
Pagtatanong
Detalye

01
Magandang Kalidad ng SFP Module - 40G QSFP+ SR4, 300m MPO 850nm JHAQC01 - JHA
2016-01-08
Mga Tampok: ◊ Sumusunod sa 40GbE XLPPI electrical specification bawat IEEE 802.3ba-2010 ◊ Sumusunod sa QSFP+ SFF-8436 Specification ◊ Pinagsama-samang bandwidth ng > 40Gbps ◊ Gumagana sa 10.3125 Gbps bawat electrical channel na may 64b/66 na compliant na data ng kuryente ng higit sa 100m transmission sa OM3 Multimode Fiber (MMF)at 150m sa OM4 MMF ◊ Single +3.3V power supply operating ◊ Walang mga digital diagnostic function ◊ Temperatura range 0°C hanggang 70°C ◊ RoHS Compliant Part ◊ Gumagamit ng karaniwang LC duplex fiber cable na nagpapahintulot sa muling paggamit ng umiiral na imprastraktura ng cable Mga Application: ◊ 40 Gigabit Ethernet interconnects ◊ Datacom/Telecom switch at mga koneksyon ng router ◊ Pagsasama-sama ng data at mga backplane na application ◊ Proprietary protocol at density ng mga application Paglalarawan: Ito ay isang Four-Channel,Pluggable, LC Duplex, Fiber-Optic QSFP+ Transceiver para sa 40 Gigabit Ethernet Applications. Ang transceiver na ito ay isang high performance module para sa short-range na duplex data communication at mga interconnect na application. Pinagsasama nito ang apat na electrical data lane sa bawat direksyon patungo sa transmission sa isang solong LC duplex fiber optic cable. Ang bawat electrical lane ay gumagana sa 10.3125 Gbps at umaayon sa 40GE XLPPI interface. Ang transceiver ay panloob na nagpaparami ng isang XLPPI 4x10G interface sa dalawang 20Gb/s na mga de-koryenteng channel, na nagpapadala at tumatanggap ng bawat optically sa isang simplex na LC fiber gamit ang bi-directional optics. Nagreresulta ito sa isang pinagsama-samang bandwidth na 40Gbps sa isang duplex LC cable. Nagbibigay-daan ito sa muling paggamit ng naka-install na LC duplex cabling infrastructure para sa 40GbE application. Sinusuportahan ang mga distansya ng link hanggang 100 m gamit ang OM3 at 150m gamit ang OM4 optical fiber. Ang mga module na ito ay idinisenyo upang gumana sa multimode fiber system gamit ang isang nominal na wavelength na 850nm sa isang dulo at 900nm sa kabilang dulo. Gumagamit ang electrical interface ng 38 contact QSFP+ type edge connector. Ang optical interface ay gumagamit ng conventional LC duplex connector. Transceiver Block Diagram • Symbol Min. Karaniwang Max. Temperatura ng Imbakan ng Yunit TS -40 +85 °C Supply Voltage VCCT, R -0.5 4 V Relative Humidity RH 0 85 % • Inirerekomendang Operating Environment: Parameter Symbol Min. Karaniwang Max. Temperatura ng pagpapatakbo ng Unit Case TC 0 +70 °C Supply Voltage VCCT, R +3.13 3.3 +3.47 V Kasalukuyang ICC 1000 mA Power Dissipation PD 3.5 W • Mga Katangian ng Elektrisidad (TOP = 0 hanggang 70 °C, VCC = 3.13 hanggang 3.47 Volts Parameter Simbolo Min Typ Max Unit Note Rate ng Data bawat Channel - 10.3125 11.2 Gbps Power Consumption - 2.5 3.5 W Supply Current Icc 0.75 1.0 A Control I/O Voltage-High VIH 2.0 Vcc V Control I/O Voltage-Mababang VIL 0 0.7 V Inter-Channel Skew TSK 150L Tagal ng RESET De US - igiit ang oras 100 ms Power On Time 100 ms Transmitter Single Ended Output Voltage Tolerance 0.3 4 V 1 Common mode Voltage Tolerance 15 mV Transmit Input Diff Voltage VI 120 1200 mV Transmit Input Diff Impedance ZIN 80 100 120 Data Dependent UI 100 120 Input ng Data UI TJ 0.28 UI Receiver Single Ended Output Voltage Tolerance 0.3 4 V Rx Output Diff Voltage Vo 600 800 mV Rx Output Rise and Fall Voltage Tr/Tf 35 ps 1 Total Jitter TJ 0.7 UI Deterministic Jitter UI Note ~ 0.82% Optical Jitter UI DJ 0.82% UI Mga Parameter(TOP = 0 hanggang 70 °C, VCC = 3.0 hanggang 3.6 Volts) Simbolo ng Parameter Min Typ Max Unit Ref. Transmitter Optical Wavelength CH1 λ 832 850 868 nm Optical Wavelength CH2 λ 882 900 918 nm RMS Spectral Lapad Pm 0.5 0.65 nm Average na Optical Power bawat Channel Pavg -4 -2.5 +5.0 dBm Optical na Lapad ng Channel0. 3.5 dB Relative Intensity Noise Rin -128 dB/HZ 1 Optical Return Loss Tolerance 12 dB Receiver Optical Center Wavelength CH1 λ 882 900 918 nm Optical Center Wavelength CH2 λ 832 850 868 nm Receiver ng Channel ng Optical na Receiver - PMAX Maximum na Sensitivity per PMAX +0.5 dBm Receiver Reflectance Rrx -12 dB LOS De-Assert LOSD -14 dBm LOS Assert LOSA -30 dBm LOS Hysteresis LOSH 0.5 dB Note 12dB Reflection Page02 ay User EEPROM at ang format nito ay napagpasyahan ng user. Ang detalyadong paglalarawan ng mababang memorya at page00.page03 itaas na memorya mangyaring tingnan ang dokumentong SFF-8436. • Timing para sa Soft Control at Status Functions Parameter Symbol Max Unit Conditions Initialization Time t_init 2000 ms Oras mula sa power on1, mainit na plug o tumataas na gilid ng I-reset hanggang ang module ay ganap na gumagana2 I-reset ang Init Assert Time t_reset_init 2 μs Isang Reset ay nabuo sa pamamagitan ng isang mababang mas mahaba kaysa sa minimum na reset pulse time na nasa ResetL pin. Oras ng Handa ng Serial Bus Hardware t_serial 2000 ms Oras mula sa power on1 hanggang sa tumugon ang module sa paghahatid ng data sa pamamagitan ng 2-wire serial bus Monitor Data ReadyTime t_data 2000 ms Oras mula sa power on1 hanggang sa data na hindi handa, bit 0 ng Byte 2, deasserted at IntL asserted I-reset ang Assert Time t_reset 2000 ms Oras mula sa tumataas na gilid sa ResetL pin hanggang sa ganap na ang module functional2 LPMode Assert Time ton_LPMode 100 μs Oras mula sa assertion ng LPMode (Vin:LPMode =Vih) hanggang sa pumasok ang power consumption ng module sa mas mababang Power Level IntL Assert Time ton_IntL 200 ms Oras mula sa paglitaw ng kundisyon na nagti-trigger ng IntL hanggang Vout:IntL = Vol IntL Time toff_IntL Time 500 μs toff_IntL 500 μs Oras mula sa malinaw sa read3 na operasyon ng nauugnay na flag hanggang Vout:IntL = Voh. Kabilang dito ang mga oras ng deassert para sa Rx LOS, Tx Fault at iba pang flag bits. Rx LOS Assert Time ton_los 100 ms Oras mula Rx LOS state hanggang Rx LOS bit set at IntL asserted Flag Assert Time ton_flag 200 ms Oras mula sa paglitaw ng kundisyon na nagti-trigger ng flag hanggang sa nauugnay na flag bit set at IntL asserted Mask Assert Time ton_mask 100 ms Oras mula sa mask bit set4 hanggang sa ang nauugnay na IntL assertion ay inhibited Mask De-assert Time toff_mask 100 ms Oras mula sa mask bit na-clear4 hanggang sa nauugnay na operasyon ng IntlL ay nagpapatuloy sa ModSelL Assert Time ton_ModSelL 100 μs Oras mula sa assertion ng ModSelL hanggang tumugon ang module sa paghahatid ng data sa 2-wire serial bus na ModSelL Deassert Time toff_ModSelL 100 μs na Oras mula sa ModSelL 100 μs na Oras mula sa ModSelL 100 μs na Oras module ay hindi tumutugon sa paghahatid ng data sa ibabaw ng 2-wire serial bus Power_over-ride oPower-set Assert Time ton_Pdown 100 ms Oras mula P_Down bit set 4 hanggang module power consumption ay pumasok sa mas mababang Power Level Power_over-ride o Power-set De-assert Time toff_Pdown 300 ms Oras mula P_Down bit clear4 hanggang ang module ay fully functional3 Tandaan: 1. Ang power on ay tinukoy bilang ang instant kapag umabot ang mga boltahe ng supply at nananatili sa o higit sa minimum tinukoy na halaga. 2. Ang fully functional ay tinukoy bilang IntL asserted dahil sa data not ready bit, bit 0 byte 2 de-asserted. 3. Sinusukat mula sa bumabagsak na gilid ng orasan pagkatapos huminto ng kaunting nabasang transaksyon. 4. Sinusukat mula sa bumabagsak na gilid ng orasan pagkatapos ng stop bit ng write transaction. • Pin Assignment Diagram ng Host Board Connector Block Pin Numbers and Name • Pin Description Pin Logic Symbol Name/Description Ref. 1 GND Ground 1 2 CML-I Tx2n Transmitter Inverted Data Input 3 CML-I Tx2p Transmitter Non-Inverted Data output 4 GND Ground 1 5 CML-I Tx4n Transmitter Inverted Data Output 6 CML-I Tx4p Transmitter Non-Inverted Data Output 7 Ground 1 8 LVTTL-I ModSelL Module Piliin ang 9 LVTTL-I ResetL Module Reset 10 VccRx +3.3V Power Supply Receiver 2 11 LVCMOS-I/O SCL 2-Wire Serial Interface Clock 12 LVCMOS-I/O SDA 2-Wire Serial Interface Data 13 GND Ground 1 14 CML- O Rx3p Receiver Inverted Data Output 15 CML-O Rx3n Receiver Non-Inverted Data Output 16 GND Ground 1 17 CML-O Rx1p Receiver Inverted Data Output 18 CML-O Rx1n Receiver Non-Inverted Data Output 19 GND Ground 1 20 GND Ground 1 21 CML-O Rx1n Receiver Non-Inverted Data Output 19 GND Ground 1 20 GND Ground 1 21 CML-O Receiver Invert Data Invert2n2 -O Rx2p Receiver Non-Inverted Data Output 23 GND Ground 1 24 CML-O Rx4n Receiver Inverted Data Output 25 CML-O Rx4p Receiver Non-Inverted Data Output 26 GND Ground 1 27 LVTTL-O ModPrsL LVT Interrupted na Module 27 LVTTL-O ModPrsL LVT na Interrupt 28 LVTTL 28 +3.3V Power Supply Transmitter 2 30 Vcc1 +3.3V Power Supply 2 31 LVTTL-I LPMode Low Power Mode 32 GND Ground 1 33 CML-I Tx3p Transmitter Inverted Data Output 34 CML-I Tx3n Transmitter Non-Inverted GND Data Output 35 1 36 CML-I Tx1p Transmitter Inverted Data Output 37 CML-I Tx1n Transmitter Non-Inverted Data Output 38 GND Ground 1 Mga Tala: Ang GND ay ang simbolo para sa single at supply(power) na karaniwan para sa QSFP modules, Lahat ay karaniwan sa loob ng QSFP module at lahat ng module voltages ay tinutukoy sa ang potensyal na ito kung hindi man ay nabanggit. Direktang ikonekta ang mga ito sa host board signal common ground plane. Naka-disable ang laser output sa TDIS >2.0V o bukas, naka-enable sa TDIS
Pagtatanong
Detalye
























