Leave Your Message
Mga Kategorya ng Produkto
Mga Tampok na Produkto
Magandang Kalidad Industrial Ethernet Switch - 1 10/100/1000TX PoE/PoE+ at 1 1000X SFP Slot | Hindi pinamamahalaang Industrial PoE Sw...Magandang Kalidad Industrial Ethernet Switch - 1 10/100/1000TX PoE/PoE+ at 1 1000X SFP Slot | Hindi pinamamahalaang Industrial PoE Sw...
01

Magandang Kalidad Industrial Ethernet Switch - 1 10/100/1000TX PoE/PoE+ at 1 1000X SFP Slot | Hindi pinamamahalaang Industrial PoE Sw...

2016-01-08
Mga Tampok ♦ Suporta sa 1 10/100/1000Base-T(X) PoE/PoE+ port at 1 1000Base-X SFP slot. ♦ Suportahan ang IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3af/at. ♦ Suportahan ang IEEE802.3af, maximum na 15.4W power supply. ♦ Suportahan ang IEEE802.3at, maximum na 30W power supply. ♦ Industrial chip design, 15kV ESD protection, 8kV surge protection. ♦ DC48-58V redundancy power, reverse polarity protection. ♦ Industrial grade 4 na disenyo, -40-85°C operating temperature. ♦ IP40 rated aluminum alloy housing, DIN-Rail mounted. Panimula Ang JHA-IGS11P ay isang plug-and-play na hindi pinamamahalaang pang-industriyang PoE switch. Nagbibigay ang switch na ito ng 1 10/100/1000Base-T(X) Ethernet port at 1 1000Base-X SFP slot, sinusuportahan ng Ethernet port ang Power-over-Ethernet (PoE) function. Ang mga switch ay inuri bilang power source equipment (PSE), at kapag ginamit sa ganitong paraan, ang mga switch ay nagbibigay-daan sa sentralisasyon ng power supply, na nagbibigay ng hanggang 30 watts ng power bawat port at binabawasan ang pagsisikap na kailangan para sa pag-install ng kuryente. Ang mga switch ay maaaring gamitin upang paganahin ang IEEE802.3af/at standard device (PD), na inaalis ang pangangailangan para sa karagdagang mga kable. Ang JHA-IGS11P ay sumusuporta sa CE, FCC, RoHS standard, gumamit ng standard na disenyo ng industriya, proteksyon ng IP40, masungit na high-strength na metal case, power input (DC48-58V). Sinusuportahan ng switch ang IEEE802.3, IEEE802.3u, IEEE802.3x na may 10/100/1000Base-T(X), full/half-duplex, at MDI/MDI-X auto-adaptation, ang -40-85℃ operating temperature , ay maaaring matugunan ang lahat ng uri ng pang-industriyang kapaligiran na kinakailangan, na nagbibigay ng maaasahan at pang-ekonomiyang solusyon para sa iyong pang-industriyang Ethernet network. Detalye Protocol Standard IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3af/at Flow Control IEEE802.3x flow control, back press flow control Switching Performance Forwarding Rate: 7.44MppsTransmission Mode: Store at ForwardPacket Laki ng Buffer: 1MB Bandack na Plane: 10Gbps MAC Table Size: 8K Delay Time: 100,000 Oras Warranty 5-taon Dimension Order Information Model No. Paglalarawan ng Goods JHA-IGS11P Unmanaged Industrial PoE Switch, 1 10/100/1000Base-T(X) PoE/PoE+ at 1 1000Base-X SFP Slot, DIN-Rail , DC48-58V, -40-85°C Temperatura sa Pagpapatakbo JHA-IG11P Unmanaged Industrial PoE Switch, 1 10/100/1000Base-T(X) PoE/PoE+ at 1 1000Base-FX, SC Connector, Multimode, Dual Fiber, 550m, DIN-Rail, DC48-58V, -40-85 °C Operating Temperature JHA-IG11P-20 Hindi Pinamamahalaang Industrial PoE Switch, 1 10/100/1000Base-T(X) PoE/PoE+ at 1 1000Base-FX, SC Connector, Single Mode, Dual Fiber, 20Km, DIN-Rail, DC48-58V, -40-85°C Operating Temperature JHA-IG11WP -20 Unmanaged Industrial PoE Switch, 1 10/100/1000Base-T(X) PoE/PoE+ at 1 1000Base-FX, SC Connector, Single Mode, Single Fiber, 20Km, DIN-Rail, DC48-58V, -40-85°C Operating Temperature Fiber Connector: SC /ST/FC/LC(SFP Slot), Single Mode/Multimode, Dual Fiber/Single Fiber, Ang 2Km/20Km/40Km/60Km/80Km/100Km/120Km ay Opsyonal. Ang Power Supply: DC48V DIN-Rail Power Supply o Power Adapter ay Opsyonal.
Pagtatanong
Detalye
Pinagmumulan ng factory na Pamamahala ng Network Switch - 24+1+1 10G Data Center Ethernet Switch JHA-SWG0124MG-24BC - JHAPinagmumulan ng factory na Pamamahala ng Network Switch - 24+1+1 10G Data Center Ethernet Switch JHA-SWG0124MG-24BC - JHA
01

Pinagmumulan ng factory na Pamamahala ng Network Switch - 24+1+1 10G Data Center Ethernet Switch JHA-SWG0124MG-24BC - JHA

2016-01-08
24+1+1 10G Data Center Ethernet Switch JHA-SWG0124MG-24BC ♦ Pangkalahatang-ideya ng produkto JHA-SWG0124MG-24BC, na isang 10 Gigabit data center switch. Nagbibigay ng 484Gbps switching capacity, ang pinakamataas na performance (1U TOR) sa industriya. Sa 360.092Mpps forwarding performance, L2/L3 full wire-speed forwarding. Gamit ang modular na disenyo, nagbibigay ito ng 24 10G SFP+ optical port, 1 Console port, 1 10/100/1000M RJ45 electrical port, na nag-aalok ng sapat na bandwidth para sa pagsasama-sama ng data at pagpapalitan ng data. At upang madaling tumugon sa mga kinakailangan sa network, maaaring pumili ang mga user ng naaangkop, 10G port ayon sa kanilang mga pangangailangan. Na may mataas na bandwidth at mababang latency, pipe network. Ang UK6500-24HC switch na matatagpuan sa density ng susunod na henerasyon ng data center at cloud computing network access, ay maaari ding gamitin para sa malalaking Internet cafe, ang core ng enterprise network, metropolitan area network, o pagtitipon. ♦ Tampok ng Produkto ★ ★ High density 10G access, kapansin-pansin ang performance (1)may 480Gbps backplane capacity, ang industriya ang pinakamataas na performance (1U TOR); (2)hardware routing, ang packet forwarding rate ng wire speed layer 3 switching ay umabot na sa 360.092Mpps, L2 / L3 full speed forwarding; (3)24 10Gb optical port, ang pinakamataas na density (1U TOR), ay nakakatugon sa pangangailangan ng high-density 10G server access. ★ ★ Maginhawang Pagpapanatili (1)mapapamahalaan sa pamamagitan ng Web, SNMP,etc (2)sumusuporta sa XModem protocol, gumamit ng TFTP/ZMODEM para sa pag-upgrade ng software at pag-upgrade ng BootRom (3)suporta sa SFP+, sabay-sabay pababang compatible sa XFP (4) configuration ★ ★ Napakahusay na Daloy at Pamamahala ng Broadcast (1)awtomatikong makita at kontrolin ang broadcast storm, suportahan ang IGMP packet detection, epektibong limitahan ang pagbaha ng mga broadcast packet. (2)suportahan ang interface ng Ethernet na kumukuha ng 1M bilang haba ng hakbang para sa paglilimita sa rate ★ ★ Ligtas at Maaasahan (1)magbigay ng DOS, DDOS, spoofing at pagtatanggol ng virus (2)suporta sa IEEE802.1x, magbigay ng pagpapatunay ng user na nakabatay sa port, kalasag sa network, kontrol sa kaligtasan, at teknolohiya sa pagkontrol ng patakaran (3)paghigpitan ang maximum na bilang ng mga host na konektado sa port, multi-binding Ethernet interface , pagtaas ng bandwidth at system redundancy ♦ Mga Teknikal na Parameter ng Produkto Modelo ng Produkto 24+1+1 Fixed Port 24 10G SFP+ optical port,1 10/100/1000M RJ45 adaptive electrical port Console Port 1 Backplane bandwidth 484Gbps 3 Packet forwarding rate 484Gbps 3 Packet forwarding Mpps Jumbo Frames 12k bytes Transfer Mode Suportahan ang store-forward mode at cut-through mode IPv4/IPv6 Route 512/256 Packet Buffer 4MB VLAN ID 4K Flash Memory Capacity 32M Kapasidad ng memorya 256MB CPU Single-Core 32-bit 600MHz MIPS Security Feature IP+MAC+PORT+ VLAN binding ARP inspection Pag-iwas sa DOS Proteksyon sa port Proteksyon sa port ng IP source VLAN Port based VLAN 802.1Q VLAN IP based VLAN MAC based VLAN MAC Address Table Static MAC address table Dynamic MAC address table Pagkontrol ng Bagyo Pagpigil sa broadcast Multicast na pagsugpo sa DLF Paglilimita sa rate ng Flow Control Half-duplex na kontrol batay sa uri ng back pressure Full-duplex na kontrol batay sa PAUSE frame Port Mirroring Suporta sa port mirroring Pamamahala ng Port Pangkalahatang setting Pagbilang ng port Pag-configure ng port Port trunking Port-isolation QoS IEEE 802.1Q Congestion mechanism Ang bawat port ay may 8 pagpapadala ng mga queues mapping 802.1p 8 priority IP Services Ping detection DHCP Snooping Spanning Tree MSTP(802.1s)、STP、RSTP Multicast Management IGMP Snooping multicasting packets detection System Management Support SNMP v1/v2 Support Console Support TELNET Upgrad Support Support interface WEB sa pamamagitan ng pag-upgrade ng bersyon ng Suporta sa web sa pamamagitan ng lokal na Dimensyon 440mm × 280mm × 44mm Katangian ng Power AC:90V~290V Power ≤100W Indicator Power indicator, system, koneksyon/pagpapadala at pagtanggap ng mga tagubilin Temperatura sa Kapaligiran/Humidity operating temperature:0°C~50°C(0m~1800m) -40°C~+70°C,kamag-anak halumigmig:5%RH~95%RH,Di-condensing
Pagtatanong
Detalye
OEM/ODM China Protocol Converter Gateway - Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 - JHAOEM/ODM China Protocol Converter Gateway - Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 - JHA
01

OEM/ODM China Protocol Converter Gateway - Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 - JHA

2016-01-08
Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 Pangkalahatang-ideya Ang protocol converter (interface converter) na ito ay gumagamit ng malakihang disenyo ng FPGA, ITU-T G.703 na karaniwang hindi naka-frame na E1 na mga interface at apat na 10 / 100Base-T Ethernet interface converter, 10 / 100Base-T na mga channel ililipat sa switch, HUB, mga router, bridge, o iba pang device. At sa pamamagitan ng Optical at iba pang kagamitan sa transportasyon ay inilipat, ang networking ay maaaring binubuo ng iba't ibang mga segment ng network. Ang device na ito ay isang high performance, adaptive remote Ethernet bridge. Ang maliit na sukat nito, mura, napaka-angkop para sa cost-sensitive na mga bridging application o bilang LAN extender o slicer bitstream sa imprastraktura. Maaaring awtomatikong matutunan ang patuloy na konektadong LAN MAC address sa patutunguhang address ng frame at isa pang LAN forwarding. Sa TCP / IP protocol transparent, magbigay ng seguridad para sa network ng komunikasyon sa pagitan ng iba't ibang mga aparatong interface, tuluy-tuloy na pagkakakonekta. Ang kagamitang ito ay malawakang ginagamit sa pagitan ng WAN at LAN networking, field ng pagsubaybay ng Product Photo Mini Type 19inch 1U type Mga Tampok Batay sa self-copyright IC Maaaring mapagtanto ang monitor at kontrol ng remote na kagamitan, ang data ng pamamahala ng OAM ay hindi kumuha ng timeslot ng mga user at makatipid ng E1 bandwidth Magkaroon ng function ng E1 interface loop back check, maiwasan ang converter crashed dahil sa interface loop return; Magkaroon ng indicator kapag naka-off ang device o nasira o nawalan ng signal ang linya ng E1; Maaaring itakda ang E1 na linya na hindi magpadala ng LINK signal sa Ethernet interface habang ang E1 na linya ay sira; Sinusuportahan ng interface ng Ethernet ang mga jumbo frame (1916 Bytes); 4Channel 10M/100M Ethernet interface ay maaaring ihiwalay ang bawat isa upang mapagtanto ang komunikasyon nang nakapag-iisa; Sinusuportahan ng Ethernet interface ang 10M/100M, kalahati/buong duplex na auto-Negotiation at AUTO-MDIX (crossed line at straightly connected line self-adaptable ); Magbigay ng 2 uri ng orasan: E1 master clock at E1 line clock; Magkaroon ng tatlong Loop Back Mode: E1 interface Loop Back (ANA)、Ethernet interface Loop Back(DIG)、Command ang remote Ethernet interface Loop Back(REM) Magkaroon ng pseudo random code test function, madali ang pag-install at pagpapanatili; Magbigay ng 2 impedances: 75 Ohm unbalance at 120 Ohm balance; Magkaroon ng Ethernet monitor self-reset function, ang kagamitan ay hindi patay Ethernet interface ay sumusuporta sa mga counter ng pagtanggap at pagpapadala ng frame, tumatanggap ng maling frame counter. Sinusuportahan ng E1 interface ang mga counter ng pagtanggap ng maling frame; Suportahan ang SNMP Network Management; Napagtanto monitor ng remote na kagamitan temperatura at boltahe mula sa lokal na kagamitan; Maaaring bumuo ng istraktura: Ethernet E1 Bridge(A)---E1 Optical Fiber Modem(B)---Ethernet Optical Fiber Modem (C) Parameter ♦ E1 Interface Interface Standard: sumunod sa protocol G.703; Rate ng Interface: n*64Kbps±50ppm; Code ng Interface: HDB3; E1 Impedance: 75Ω (hindi balanse), 120Ω (balanse); Jitter tolerance: Alinsunod sa protocol G.742 at G.823 Allowed Attenuation: 0~6dBm ♦ Ethernet interface(10/100M) Interface rate: 10/100 Mbps, half/full duplex auto-negotiation Interface Standard: Compatible sa IEEE 802.3 , IEEE 802.1Q (VLAN) MAC Address Capability: 4096 Connector: RJ45, suporta sa Auto-MDIX ♦ Working environment Temperatura sa pagtatrabaho: -10°C ~ 50°C Working Humidity: 5%~95 % (walang condensation) Temperatura ng storage: -40°C ~ 80°C Storage Humidity: 5 %~95 % (walang condensation) Mga Detalye Numero ng Modelo: JHA-CE1F4 Functional na Paglalarawan 1channel unframed E1 - 4FE interface converter, 10/100 adaptive, sumusuporta sa VLAN, -48V o AC220V power supply (opsyonal) Port Deskripsyon Isang E1 interface, apat na Fast Ethernet port Power Power supply: AC180V ~ 260V; DC –48V; DC +24VPower consumption : ≤10W Dimensyon Laki ng Produkto: Mini type 216X140X31mm (WXDXH),1.3KG/piraso 19inch 1U type 483X138X44mm (WXDXH),2.0KG/piraso Application
Pagtatanong
Detalye
PriceList para sa Rs485 422 Converter - Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 - JHAPriceList para sa Rs485 422 Converter - Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 - JHA
01

PriceList para sa Rs485 422 Converter - Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 - JHA

2016-01-08
Hindi naka-frame na E1-4FE interface Converter JHA-CE1F4 Pangkalahatang-ideya Ang protocol converter (interface converter) na ito ay gumagamit ng malakihang disenyo ng FPGA, ITU-T G.703 na karaniwang hindi naka-frame na E1 na mga interface at apat na 10 / 100Base-T Ethernet interface converter, 10 / 100Base-T na mga channel ililipat sa switch, HUB, mga router, bridge, o iba pang device. At sa pamamagitan ng Optical at iba pang kagamitan sa transportasyon ay inilipat, ang networking ay maaaring binubuo ng iba't ibang mga segment ng network. Ang device na ito ay isang high performance, adaptive remote Ethernet bridge. Ang maliit na sukat nito, mura, napaka-angkop para sa cost-sensitive na mga bridging application o bilang LAN extender o slicer bitstream sa imprastraktura. Maaaring awtomatikong matutunan ang patuloy na konektadong LAN MAC address sa patutunguhang address ng frame at isa pang LAN forwarding. Sa TCP / IP protocol transparent, magbigay ng seguridad para sa network ng komunikasyon sa pagitan ng iba't ibang mga aparatong interface, tuluy-tuloy na pagkakakonekta. Ang kagamitang ito ay malawakang ginagamit sa pagitan ng WAN at LAN networking, field ng pagsubaybay ng Product Photo Mini Type 19inch 1U type Mga Tampok Batay sa self-copyright IC Maaaring mapagtanto ang monitor at kontrol ng remote na kagamitan, ang data ng pamamahala ng OAM ay hindi kumuha ng timeslot ng mga user at makatipid ng E1 bandwidth Magkaroon ng function ng E1 interface loop back check, maiwasan ang converter crashed dahil sa interface loop return; Magkaroon ng indicator kapag naka-off ang device o nasira o nawalan ng signal ang linya ng E1; Maaaring itakda ang E1 na linya na hindi magpadala ng LINK signal sa Ethernet interface habang ang E1 na linya ay sira; Sinusuportahan ng interface ng Ethernet ang mga jumbo frame (1916 Bytes); 4Channel 10M/100M Ethernet interface ay maaaring ihiwalay ang bawat isa upang mapagtanto ang komunikasyon nang nakapag-iisa; Sinusuportahan ng Ethernet interface ang 10M/100M, kalahati/buong duplex na auto-Negotiation at AUTO-MDIX (crossed line at straightly connected line self-adaptable ); Magbigay ng 2 uri ng orasan: E1 master clock at E1 line clock; Magkaroon ng tatlong Loop Back Mode: E1 interface Loop Back (ANA)、Ethernet interface Loop Back(DIG)、Command ang remote Ethernet interface Loop Back(REM) Magkaroon ng pseudo random code test function, madali ang pag-install at pagpapanatili; Magbigay ng 2 impedances: 75 Ohm unbalance at 120 Ohm balance; Magkaroon ng Ethernet monitor self-reset function, ang kagamitan ay hindi patay Ethernet interface ay sumusuporta sa mga counter ng pagtanggap at pagpapadala ng frame, tumatanggap ng maling frame counter. Sinusuportahan ng E1 interface ang mga counter ng pagtanggap ng maling frame; Suportahan ang SNMP Network Management; Napagtanto monitor ng remote na kagamitan temperatura at boltahe mula sa lokal na kagamitan; Maaaring bumuo ng istraktura: Ethernet E1 Bridge(A)---E1 Optical Fiber Modem(B)---Ethernet Optical Fiber Modem (C) Parameter ♦ E1 Interface Interface Standard: sumunod sa protocol G.703; Rate ng Interface: n*64Kbps±50ppm; Code ng Interface: HDB3; E1 Impedance: 75Ω (hindi balanse), 120Ω (balanse); Jitter tolerance: Alinsunod sa protocol G.742 at G.823 Allowed Attenuation: 0~6dBm ♦ Ethernet interface(10/100M) Interface rate: 10/100 Mbps, half/full duplex auto-negotiation Interface Standard: Compatible sa IEEE 802.3 , IEEE 802.1Q (VLAN) MAC Address Capability: 4096 Connector: RJ45, suporta sa Auto-MDIX ♦ Working environment Temperatura sa pagtatrabaho: -10°C ~ 50°C Working Humidity: 5%~95 % (walang condensation) Temperatura ng storage: -40°C ~ 80°C Storage Humidity: 5 %~95 % (walang condensation) Mga Detalye Numero ng Modelo: JHA-CE1F4 Functional na Paglalarawan 1channel unframed E1 - 4FE interface converter, 10/100 adaptive, sumusuporta sa VLAN, -48V o AC220V power supply (opsyonal) Port Deskripsyon Isang E1 interface, apat na Fast Ethernet port Power Power supply: AC180V ~ 260V; DC –48V; DC +24VPower consumption : ≤10W Dimensyon Laki ng Produkto: Mini type 216X140X31mm (WXDXH),1.3KG/piraso 19inch 1U type 483X138X44mm (WXDXH),2.0KG/piraso Application
Pagtatanong
Detalye
Magandang Kalidad WDM - DWDM Device - JHAMagandang Kalidad WDM - DWDM Device - JHA
01

Magandang Kalidad WDM - DWDM Device - JHA

2016-01-08
1. Mga Tampok ♦ Mababang Insertion Loss ♦ High Isolation ♦ Mababang PDL ♦ Compact Design ♦ Malapad na Operating Wavelength: 1460nm~1620nm ♦ Malapad na Operating Temperature: -5℃~75℃ ♦ PON High Reliability and Stability Network ♦ D Applications Stability 2. ♦ Mga Link ng CATV 3. Pagsunod ♦ Telcordia GR-1209-CORE-2001 ♦ Telcordia GR-1221-CORE-1999 ♦ ITU-T G.694.1 ♦ RoHS 4. Mga Detalye Mga Parameter ng Channel Space(nm) 100Ghz Center Space(nm) Accucy (nm) ±0.05 ±0.1 Channel Passband(@-0.5dB) (nm) 0.22 0.5 Transmission band IL (dB) ≤1.0 ≤0.9 Reflection band IL (dB) ≤0.4 ≤0.4 Transmission band Isolation (dB) ≤0.4 Transmission band Isolation (dB) Paghihiwalay (dB) ≥10 Fiber Type SMF-28e o tinukoy ng customer Center Wavelength ITU Grid Ripple (dB) ≤0.3 Polarization Dependent Loss (dB) ≤0.1 Polarization Mode Dispersion (ps) ≤0.1 RL (dB) ≥45 Optical Optical (dB) ≥45 Power (mw) 500 Operating Temperature (℃) -5~75 Storage Temperature (℃) -40~85 Package Dimension (mm) (Φ*L) 5.5*34/5.5*38 Mga Tala: 1. Tinukoy nang walang connector. 2. Magdagdag ng karagdagang 0.2dB na pagkawala sa bawat connector. Mga Mechanical na Dimensyon Φ5*5*34 6.Impormasyon sa Pag-order LWD -XX X XX X XX -XXX Port Configuration WDM Type Center Wavelength Fiber Type Output Fiber Length Com Pass Reflection L-Lintegrity 01=1X1 C=CWDM 1460-1620 27=1270 1271 B=250um na walang hibla 10=1.0m 0=Wala 0=Wala 0=Wala W=WDM 02=1X2 Q=CWDM 1260-1620 ……. L=900um loose tube 15=1.5m 1=FC/UPC 1=FC/UPC 1=FC/UPC D=Device F=FWDM 61=1610/1611 T=900um tight buffer 20=2.0m 2=FC/APC 2 =FC/APC 2=FC/APC X=100G DWDM 21=21CH …… 3=SC/UPC 3=SC/UPC 3=SC/UPC Y=200G DWDM ……. XX= Customized 4=SC/APC 4=SC/APC 4=SC/APC 49=49CH 5=LC/UPC 5=LC/UPC 5=LC/UPC F1=T13/R15 6=LC/APC 6=LC/ APC 6=LC/APC F2=T15/R13 X= Customized X= Customized X= Customized F3=T13/R1415 F4=T14/R1315 F5=T15/R1314 F6=T1415/R13 F7=T1314/R15 XX=Customized
Pagtatanong
Detalye
Magandang Kalidad ng Fiber Media Converter - 10/100TX – 100FX Dual Fiber | USB Fiber Media Converter JHA-F11U - JHAMagandang Kalidad ng Fiber Media Converter - 10/100TX – 100FX Dual Fiber | USB Fiber Media Converter JHA-F11U - JHA
01

Magandang Kalidad ng Fiber Media Converter - 10/100TX – 100FX Dual Fiber | USB Fiber Media Converter JHA-F11U - JHA

2016-01-08
Panimula Ang JHA-F11U Series Fiber Media Converters ay maaaring mag-convert ng Optical - Electric Ethernet signal sa pagitan ng 10/100M UTP interface (TX) at 100M optical fiber interface (FX). Maaari nitong pahabain ang tradisyonal na 10/100M mabilis na Ethernet sa layo na 120km sa pamamagitan ng optical fiber link. Ito ay nagtataglay ng matatag na pagganap at magandang kalidad sa pamamagitan ng paggamit ng pinakabagong mga pakete ng IC mula sa USA at Taiwan. Maaaring ganap na masubaybayan ng 6 Group LED na mga ilaw ang mga kondisyon sa pagtatrabaho ng mga Converter. Madali para sa mga end-user na obserbahan ang operasyon ng network. DM02/DS02 series external power supply Converters ay maaaring gamitin nang mag-isa, o ipasok sa 14 na slots Converters Rack. Ito ay angkop para sa paggamit ng Network Center. Maaaring suportahan ng serye ng JHA-F11U ang USB power supply, na ginagawang mas maginhawa ang fiber to table. Ang pagkakaroon ng 5 DIP switch, ang serye ng JHA-F11U ay nagpapadali sa customer na pamahalaan ang mga item. Mga Tampok ♦ Ang function ng auto negotiation ay nagbibigay-daan sa UTP port na awtomatikong pumili ng 10M o 100M, at Full Duplex o Half Duplex. ♦ Sinusuportahan ng UTP port ang MDI/MDI-X na auto crossover. ♦ LFP (Link Fault Pass-through): Kapag ang optical fiber o UTP ang may kasalanan, maaaring ihinto ng converter ang lahat ng link. ♦ Maaaring pumili ng Maramihang Optical Transceiver: SC, ST o FC, singlemode / multimode ♦ Sumusuporta sa 1600 bytes packet para sa pamamahala ♦ Maaaring piliin ang mode na gumagana ng Converter: Store at forward switch mode, Modified cut-through switch mode, o Converter mode. ♦ Ang Internal Circuit ng napigilang pagkulog ay maaaring lubos na mabawasan ang pinsala ng converter na dulot ng thunderbolt induction. ♦ Internal o External switching power: para piliin ng mga user. ♦ DIP SWITCH Switch Function Switch Function Switch 1 Auto UTP Nway Force UTP opsyonal na Switch 2 100 UTP100M 10 UTP10M Switch 3 FDX UTP Full Duplex HDX UTP Half Duplex Switch 4 LFP LFP available LFP DIS LFP Hindi available Switch 5 FDX Optical Full Duplex HDX Optical Half Duplex Switch 6 FDX Converter model SW Pagtutukoy ng modelo ng switch ♦ Mga pamantayan sa pagpapatakbo: IEEE802.3u, 10/100Base-TX at 100Base-FX;. ♦ Talahanayan ng mga MAC address: 1K ♦ Buffer ng data: Built-in na 128Kbyte RAM . ♦ Mga Konektor: Konektor ng UTP: RJ-45, 10/100Mbps; Fiber Connector: ST/SC/FC, 100Mbps ♦ Cable: UTP: Cat. 5 (ang max na distansya hanggang 100m) Fiber ( Multimode): 50/125, 62.5/125μm(ang maximum na distansya hanggang 2km o 5km) Fiber ( Singlemode): 8.3/125, 8.7/125, 9/125, 10/ 125μm(ang max na distansya hanggang 20 -120km) ♦ Flow Control Full Duplex: Sumusuporta sa standard na IEEE802.3x Half Duplex: back pressure ♦ LED: Power, FX SD, FX Link/Act, TX 100, TX FDX, TX Link/Act. ♦ Power Requirement: External Power supply Input:85-245VAC 50Hz o DC 48V Output:5VDC 1A USB power supply:5VDC 1A ♦ Ambient Temperature: 0 ~ 70℃ ♦ Humidity: 5 ~ 90% ♦ ♦ 90% ♦ ♦ 90% Panlabas na kapangyarihan: oo Impormasyon ng Order Hindi Modelo. Paglalarawan ng Mga Kalakal JHA-F11U 10/100M Multimode, Dual Fiber, 2Km, SC/ST/FC/LC Connector JHA-F11U-20 10/100M Single-mode, Dual Fiber, 20Km, SC/ST /FC/LC Connector JHA-F11WU-20 10/100M Single-mode, Single Fiber,20Km, SC/ST/FC/LC Connector JHA-FS11U 1*100Base-X SFP Slot + 1*10/100Base-T(X) RJ45 Port
Pagtatanong
Detalye
Mataas na reputasyon Active Optical Cable - QSFP+/4-SFP+ Active Optical Cable JHA-QSFP-4SFP-40G-AOC - JHAMataas na reputasyon Active Optical Cable - QSFP+/4-SFP+ Active Optical Cable JHA-QSFP-4SFP-40G-AOC - JHA
01

Mataas na reputasyon Active Optical Cable - QSFP+/4-SFP+ Active Optical Cable JHA-QSFP-4SFP-40G-AOC - JHA

2016-01-08
◊ Suportahan ang 40-4*10GBASE-SR application ◊ Electrical interface na sumusunod sa QSFP+ connector (SFF-8436) at SFP+ connector (SFF-8431) ◊ 850nm VCSEL transmitter, PIN photo-detector receiver ◊ Multi rate na hanggang 10.3125Gbps bawat lane ◊ Temperatura ng operating case: 0 hanggang 70 ℃ ◊ +3.3V power supply voltage ◊ Mababang paggamit ng kuryente ◊ RoHS compliant ◊ UL certification cables (opsyonal) Applications ◊ 40-4*10 Gbe-SR ◊ Fiber Channel Applications ◊ InfiniBand QDR, SDR, DDR ◊ Server, switch, storage at host card mga adaptor, atbp. Mga Detalye: Absolute Maximum Ratings Parameter Symbol Min Typical Max Unit Storage Temperature TS -10 - +85 ℃ Operating Humidity RH +5 - +85 % Supply Voltage VCC -0.5 +3.3 +3.6 V Inirerekomendang Operating Condition Parameter Symbol Min Typical Max Unit Operating Case Temperatura TC 0 +70 ℃ Supply Voltage VCC +3.14 +3.3 +3.47 V Supply current (QSFP+) ICC - - 450 mA Supply current (SFP+)(bawat terminal) - - 150 mA Channel Data Rate Dr 10.3125 - Gbps Fiber bend radius - 3 - - CM Electrical at Optical na katangian Sinusukat na kondisyon: Rate ng Data ng Channel 10.3125Gbps, VRCCR=3.3V, PRBS31, Case Temperatura ng Operating 0~70℃ Simbolo ng Parameter ng Transmitter Min Tipikal na Max Unit Center Wavelength λc 830 850 870 nm RMS spectral width Pm - - 0.45 nm Average na lakas ng paglulunsad, bawat lane PAVG -6.0 - +2.4 dBm Extinction Ratio -ER dB 3.0 different input swing Vin PP 200 - 1600 mV Input differential impedance Zin 90 100 110 Ω Receiver Parameter Symbol Min Typical Max Unit Center Wavelength λc 830 850 870 nm Bit Error Rate BER - - E-12 Differential Data Output Swing Vout PP 400 - mped100 Differential Output 1000 110 Ω QSFP + Mga Paglalarawan ng Pin Pangalan ng PIN Function/Paglalarawan 1 GND Module Ground 2 Tx2n Transmitter inverted data input 3 Tx2p Transmitter non-inverted data input 4 GND Module Ground 5 Tx4n Transmitter inverted data input 6 Tx4p Transmitter 7 GND non-inverted data input Ground 8 MODSEIL Module Select 9 ResetL Pag-reset ng Module 10 VCCRx +3.3v Receiver Power Supply 11 SCL 2-wire Serial interface clock 12 SDA 2-wire Serial interface data 13 GND Module Ground 14 RX3p Receiver non-inverted data output 15 RX3n Receiver inverted data output 16 Power Supply GND na output ng data 16 Power Supply RX1p Receiver non-inverted data output 18 RX1n Receiver inverted data output 19 GND Module Ground 20 GND Module Ground 21 RX2n Receiver inverted data output 22 RX2p Receiver non-inverted data output 23 GND Module Ground 24 RX4n data Receiver inverted data output 22 RX2p Receiver non-inverted data output 23 GND Module Ground 24 RX4n data Receiver 2 Receiver non-inverted RX4n data output Inverted output 26 GND Module Ground 27 ModPrsL Module Present, internal pulled down to GND 28 IntL Interrupt output, dapat i-pull up sa host board 29 VCCTx +3.3v Transmitter Power Supply 30 VCC1 +3.3v Power Supply 31 LPMode Low Power Mode 32 GND Module Ground 33 Tx3p Transmitter non-inverted data input 34 Tx3n Transmitter inverted data input 35 GND Module Ground 36 Tx1p Transmitter non-inverted data input 37 Tx1n Transmitter inverted data input 38 GND Module Ground SFP + Pin Deskripsyon Pin Symbol Name/Description Notes 1 VEET Module Transmitter Ground 1 2 TX_FAULT ISABLE Module ng Transmitter TX_FAULT_D Hindi Paganahin ang Transmitter; Ino-off ang transmitter laser output 3 4 SDA 2-Wire Serial Interface Data Line (MOD-DEF2) 5 SCL 2-Wire Serial Interface Clock (MOD-DEF1) 6 MOD_ABS Module Absent, konektado sa VEET o VEER sa module 2 7 RS0 Rate Piliin ang 0, opsyonal na kinokontrol ang SFP+ module receiver 8 RX_LOS Receiver Loss of Signal Indikasyon (Sa FC na itinalaga bilang Rx_LOS at sa Ethernet itinalaga bilang HINDI Signal Detect) 2 9 RS1 Rate Select 1, opsyonal na kinokontrol ang SFP+ module transmitter 10 VEER Module Receiver Ground 1 11 VEER Module Receiver Ground 1 12 RD- Receiver 13 Inverted Data Output 13 Receiver Non-Inverted Data Output 14 VEER Module Receiver Ground 1 15 VCCR Module Receiver 3.3 V Supply 16 VCCT Module Transmitter 3.3 V Supply 17 VEET Module Transmitter Ground 1 18 TD+ Transmitter Non-Inverted Data Input 19 TD- Transmitter Module ng Transmitter na Inverted Ground 20 ng Data 1 Haba ng Cable L1(Yunit: m) Mapagparaya(Unit: cm) <1.0 +5/-0 1.0~4.5 +15/-0 5.0~14.5 +30/-0 ≥15.0 +2%/-0 Haba ng Talahanayan 2 L1 (Yunit: m) Haba L2(Yunit: m) 1.0 0.7 2 1.4 3 2 ≥5.0 3 Mga Babala Mga Pag-iingat sa Paghawak: Ang device na ito ay madaling masira bilang resulta ng electrostatic discharge (ESD). Ang isang static na libreng kapaligiran ay lubos na inirerekomenda. Sundin ang mga alituntunin ayon sa wastong pamamaraan ng ESD. Kaligtasan ng Laser: Ang radiation na ibinubuga ng mga laser device ay maaaring mapanganib sa mata ng tao. Iwasan ang pagkakalantad ng mata sa direkta o hindi direktang radiation.
Pagtatanong
Detalye
Factory Supply Compatible 3m Sfp+ Aoc Para sa Router Connection - QSFP+/4-SFP+ Active Optical Cables JHA-QSFP-4SFP-40G-A...Factory Supply Compatible 3m Sfp+ Aoc Para sa Router Connection - QSFP+/4-SFP+ Active Optical Cables JHA-QSFP-4SFP-40G-A...
01

Factory Supply Compatible 3m Sfp+ Aoc Para sa Router Connection - QSFP+/4-SFP+ Active Optical Cables JHA-QSFP-4SFP-40G-A...

2016-01-08
◊ Suportahan ang 40-4*10GBASE-SR application ◊ Electrical interface na sumusunod sa QSFP+ connector (SFF-8436) at SFP+ connector (SFF-8431) ◊ 850nm VCSEL transmitter, PIN photo-detector receiver ◊ Multi rate na hanggang 10.3125Gbps bawat lane ◊ Temperatura ng operating case: 0 hanggang 70 ℃ ◊ +3.3V power supply voltage ◊ Mababang paggamit ng kuryente ◊ RoHS compliant ◊ UL certification cables (opsyonal) Applications ◊ 40-4*10 Gbe-SR ◊ Fiber Channel Applications ◊ InfiniBand QDR, SDR, DDR ◊ Server, switch, storage at host card mga adaptor, atbp. Mga Detalye: Absolute Maximum Ratings Parameter Symbol Min Typical Max Unit Storage Temperature TS -10 - +85 ℃ Operating Humidity RH +5 - +85 % Supply Voltage VCC -0.5 +3.3 +3.6 V Inirerekomendang Operating Condition Parameter Symbol Min Typical Max Unit Operating Case Temperatura TC 0 +70 ℃ Supply Voltage VCC +3.14 +3.3 +3.47 V Supply current (QSFP+) ICC - - 450 mA Supply current (SFP+)(bawat terminal) - - 150 mA Channel Data Rate Dr 10.3125 - Gbps Fiber bend radius - 3 - - CM Electrical at Optical na katangian Sinusukat na kondisyon: Rate ng Data ng Channel 10.3125Gbps, VRCCR=3.3V, PRBS31, Case Temperatura ng Operating 0~70℃ Simbolo ng Parameter ng Transmitter Min Tipikal na Max Unit Center Wavelength λc 830 850 870 nm RMS spectral width Pm - - 0.45 nm Average na lakas ng paglulunsad, bawat lane PAVG -6.0 - +2.4 dBm Extinction Ratio -ER dB 3.0 different input swing Vin PP 200 - 1600 mV Input differential impedance Zin 90 100 110 Ω Receiver Parameter Symbol Min Typical Max Unit Center Wavelength λc 830 850 870 nm Bit Error Rate BER - - E-12 Differential Data Output Swing Vout PP 400 - mped100 Differential Output 1000 110 Ω QSFP + Mga Paglalarawan ng Pin Pangalan ng PIN Function/Paglalarawan 1 GND Module Ground 2 Tx2n Transmitter inverted data input 3 Tx2p Transmitter non-inverted data input 4 GND Module Ground 5 Tx4n Transmitter inverted data input 6 Tx4p Transmitter 7 GND non-inverted data input Ground 8 MODSEIL Module Select 9 ResetL Pag-reset ng Module 10 VCCRx +3.3v Receiver Power Supply 11 SCL 2-wire Serial interface clock 12 SDA 2-wire Serial interface data 13 GND Module Ground 14 RX3p Receiver non-inverted data output 15 RX3n Receiver inverted data output 16 Power Supply GND na output ng data 16 Power Supply RX1p Receiver non-inverted data output 18 RX1n Receiver inverted data output 19 GND Module Ground 20 GND Module Ground 21 RX2n Receiver inverted data output 22 RX2p Receiver non-inverted data output 23 GND Module Ground 24 RX4n data Receiver inverted data output 22 RX2p Receiver non-inverted data output 23 GND Module Ground 24 RX4n data Receiver 2 Receiver non-inverted RX4n data output Inverted output 26 GND Module Ground 27 ModPrsL Module Present, internal pulled down to GND 28 IntL Interrupt output, dapat i-pull up sa host board 29 VCCTx +3.3v Transmitter Power Supply 30 VCC1 +3.3v Power Supply 31 LPMode Low Power Mode 32 GND Module Ground 33 Tx3p Transmitter non-inverted data input 34 Tx3n Transmitter inverted data input 35 GND Module Ground 36 Tx1p Transmitter non-inverted data input 37 Tx1n Transmitter inverted data input 38 GND Module Ground SFP + Pin Deskripsyon Pin Symbol Name/Description Notes 1 VEET Module Transmitter Ground 1 2 TX_FAULT ISABLE Module ng Transmitter TX_FAULT_D Hindi Paganahin ang Transmitter; Ino-off ang transmitter laser output 3 4 SDA 2-Wire Serial Interface Data Line (MOD-DEF2) 5 SCL 2-Wire Serial Interface Clock (MOD-DEF1) 6 MOD_ABS Module Absent, konektado sa VEET o VEER sa module 2 7 RS0 Rate Piliin ang 0, opsyonal na kinokontrol ang SFP+ module receiver 8 RX_LOS Receiver Loss of Signal Indikasyon (Sa FC na itinalaga bilang Rx_LOS at sa Ethernet itinalaga bilang HINDI Signal Detect) 2 9 RS1 Rate Select 1, opsyonal na kinokontrol ang SFP+ module transmitter 10 VEER Module Receiver Ground 1 11 VEER Module Receiver Ground 1 12 RD- Receiver 13 Inverted Data Output 13 Receiver Non-Inverted Data Output 14 VEER Module Receiver Ground 1 15 VCCR Module Receiver 3.3 V Supply 16 VCCT Module Transmitter 3.3 V Supply 17 VEET Module Transmitter Ground 1 18 TD+ Transmitter Non-Inverted Data Input 19 TD- Transmitter Module ng Transmitter na Inverted Ground 20 ng Data 1 Haba ng Cable L1(Yunit: m) Mapagparaya(Unit: cm) <1.0 +5/-0 1.0~4.5 +15/-0 5.0~14.5 +30/-0 ≥15.0 +2%/-0 Haba ng Talahanayan 2 L1 (Yunit: m) Haba L2(Yunit: m) 1.0 0.7 2 1.4 3 2 ≥5.0 3 Mga Babala Mga Pag-iingat sa Paghawak: Ang device na ito ay madaling masira bilang resulta ng electrostatic discharge (ESD). Ang isang static na libreng kapaligiran ay lubos na inirerekomenda. Sundin ang mga alituntunin ayon sa wastong pamamaraan ng ESD. Kaligtasan ng Laser: Ang radiation na ibinubuga ng mga laser device ay maaaring mapanganib sa mata ng tao. Iwasan ang pagkakalantad ng mata sa direkta o hindi direktang radiation.
Pagtatanong
Detalye
Magandang Kalidad WDM - CWDM Device - JHAMagandang Kalidad WDM - CWDM Device - JHA
01

Magandang Kalidad WDM - CWDM Device - JHA

2016-01-08
1. Mga Tampok ♦ Mababang Insertion Loss ♦ Mataas na Paghihiwalay ♦ Mababang PDL ♦ Compact Design ♦ Malapad na Operating Wavelength: 1260nm~1620nm ♦ Malapad na Operating Temperature: -45℃~85℃ ♦ Mataas na Reliability at Stability ng Network ng Application ♦ WDM System 2. ♦ Mga Link ng CATV 3. Pagsunod ♦ Telcordia GR-1209-CORE-2001 ♦ Telcordia GR-1221-CORE-1999 ♦ ITU-T G.694.1 ♦ RoHS 4. Mga Detalye Parameters Center Pass ng Wavelength (nm1)(nm1) ) ITU±6.5 Operating Wavelength (nm) 1260-1620 Channel Space(nm) 20 Fiber Type SMF-28e o tinukoy ng customer IL(dB) Transmission band ≤0.6 Reflection band ≤0.4 Isolation(dB) Transmission band ≥30 Reflection band ≥12 Ripple (dB) ≥12 Ripple (dB) 0.3 Polarization Dependent Loss (dB) ≤0.1 Polarization Mode Dispersion (ps) ≤0.1 RL (dB) ≥45 Directivity (dB) ≥50 Maximum Optical Power (mw) 500 Operating Temperature (℃) -5~75or-45~85 Storage Temperature (℃) -40~ 85 Dimensyon ng Package (mm) (Φ*L) 5.5*34(250um) Dimensyon ng Package (mm) (Φ*L) 5.5*38(0.9mm) Mga Tala: 1. Tinukoy nang walang connector. 2. Magdagdag ng karagdagang 0.2dB na pagkawala sa bawat connector. 5.Mga Dimensyong Mekanikal 6. Impormasyon sa Pag-order LWD XX X XX X XX XXX Port Configuration WDM Type Center Wavelength Fiber Type Output Fiber Length COM Port Connector Pass Port Connector Reflection Port Connector L-Lintegrity 01=1*1 C=CWDM 1460-1620 47 =1470/1471 B=250um na walang hibla 10=1.0m 0=Wala 0=Wala 0=Wala W=WDM 02=1*2 Q=CWDM 1260-1620 ……. L=900um loose tube 12=1.2m 1=FC/UPC 1=FC/UPC 1=FC/UPC D= Device 61=1610/1611 T=900um tight buffer 15=1.5m 2=FC/APC 2=FC/ APC 2=FC/APC …… 3=SC/UPC 3=SC/UPC 3=SC/UPC XX=Customized 4=SC/APC 4=SC/APC 4=SC/APC 5=LC/UPC 5=LC/UPC 5=LC/UPC 6=LC/APC 6=LC/APC 6=LC/APC X= Customized X= Customized X= Customized
Pagtatanong
Detalye
OEM Factory para sa Dual Fiber 10/100m - 4E1+1FE PDH Fiber Multiplexer JHA-CPE4F1 - JHAOEM Factory para sa Dual Fiber 10/100m - 4E1+1FE PDH Fiber Multiplexer JHA-CPE4F1 - JHA
01

OEM Factory para sa Dual Fiber 10/100m - 4E1+1FE PDH Fiber Multiplexer JHA-CPE4F1 - JHA

2016-01-08
Pangkalahatang-ideya ng 4E1+1FE PDH Fiber Multiplexer JHA-CPE4F1 Ang device na ito ay nagbibigay ng 1-4* E1 interface, 1*10/100M Ethernet interface (Line Speed ​​100M), Standard 2 wire na telepono bilang engineering order-wire (opsyonal). Ito ay napaka-flexible. Mayroon itong alarm function. Ang trabaho ay maaasahan, matatag, at mababang paggamit ng kuryente, mataas na pagsasama, maliit na sukat. Mga Tampok ng Larawan ng Produkto Batay sa self-copyright IC Modular wide dynamic optical detector Ethernet (Line Speed ​​100M) interface rate ay 10M/100M, half/full duplex Auto-Nego Gumagamit ng karaniwang 2 wire na telepono (mga non-telephone handle) na itinakda bilang engineering order- wire hotline(opsyonal) E1 interface ay sumusunod sa G.703, gumagamit ng digital clock recovery at makinis na phase-lock na teknolohiya Kapag nawala ang optical signal, maaari nitong makita ang remote naka-off ang device o nakadiskonekta ang fiber, at nagsasaad ng alarm sa pamamagitan ng LED Maaaring tingnan ng lokal na device ang kondisyon ng pagtatrabaho ng remote na device Magbigay ng command sa remote na interface Loop Back, i-ease ang pagpapanatili ng linya Ang distansya ng transmission ay hanggang 2-120Km nang walang pagkaantala AC 220V, DC -48V, DC+24V ay maaaring opsyonal na DC-48V/DC+24V power supply na may awtomatikong polarity detection function, kapag naka-install nang walang pagkakaiba sa pagitan ng positibo at negatibong Parameter ♦ Fiber Multi-mode Fiber 50/125um, 62.5/125um, Maximum transmission distance: 5Km @ 62.5 / 125um single mode fiber,attenuation (3dbm/km) Wave Haba: 820nm Transmitting power: -12dBm (Bm) ~-9dBm ) Sensitibo ng receiver: -28dBm (Min) Link budget: 16dBm Single-mode Fiber 8/125um, 9/125um Maximum na distansya ng transmission: 40Km Distansya ng transmission: 40Km @ 9 / 125um single mode fiber, attenuation (0.35dbm/km) Haba ng Wave: 1310n : -9dBm (Min) ~-8dBm (Max) Sensitivity ng Receiver: -27dBm (Min) Link na badyet: 18dBm ♦ E1 Interface Interface Standard: sumunod sa protocol G.703; Rate ng Interface: 2048Kbps±50ppm; Code ng Interface: HDB3; E1 Impedance: 75Ω (hindi balanse), 120Ω (balanse); Jitter tolerance: Alinsunod sa protocol G.742 at G.823 Allowed Attenuation: 0~6dBm ♦ Ethernet interface(10/100M) Interface rate: 10/100 Mbps, half/full duplex auto-negotiation Interface Standard: Compatible sa IEEE 802.3 , IEEE 802.1Q (VLAN) MAC Address Capability: 4096 Connector: RJ45, suporta sa Auto-MDIX ♦ Working environment Temperatura sa pagtatrabaho: -10°C ~ 50°C Working Humidity: 5%~95 % (walang condensation) Temperatura ng storage: -40°C ~ 80°C Storage Humidity: 5 %~95 % (walang condensation) Mga Detalye Numero ng Modelo ng Modelo:JHA-CPE4F1 Functional na Paglalarawan 4E1+1*FE PDH,mag-order ng wire phone,Desk-Top Type(Standard telephone interface, non-telephone handles) Port Deskripsyon Isang optical port,4 E1 interface (75/120 ohms),Isang FE Ethernet interface, isang engineering order- wire na interface ng telepono Power Supply: AC180V ~ 260V;DC–48V;DC+24V Power Consumo: ≤10W Sukat ng Produkto: 19 pulgada 1U 485X138X44mm(WXDXH) Timbang 2.3KG/PCS Application
Pagtatanong
Detalye
Makatwirang presyo 2 Sfp Switch - L3 24+4 10Gigabit Management Fiber Ethernet Switch JHA-SW2404MG-28BC - JHAMakatwirang presyo 2 Sfp Switch - L3 24+4 10Gigabit Management Fiber Ethernet Switch JHA-SW2404MG-28BC - JHA
01

Makatwirang presyo 2 Sfp Switch - L3 24+4 10Gigabit Management Fiber Ethernet Switch JHA-SW2404MG-28BC - JHA

2016-01-08
L3 24+4 10Gigabit Management Fiber Ethernet Switch JHA-SW2404MG-28BC L3 24+4 10Gigabit Ethernet Switch ♦ Pangkalahatang-ideya ng produkto L3 24+4 10Gigabit Ethernet Switch ay karaniwang third-layer non-blocking switch. Nagbibigay ng 24 10/100/1000Base-T Ethernet port, 4 10G SFP+ port. Batay sa teknolohiyang ASIC chip na may mataas na pagganap, ang disenyo ng modular na istraktura, na may kakayahan ng multilayer switching at wire-speed routing forwarding. Maaaring i-deploy sa metropolitan area network, at nagbibigay ng ilang huling 1 km na teknolohiya upang magtipon at mag-core ng data exchange. Kasabay nito, ang L3 24+4 10Gigabit Ethernet Switch ay nagbibigay ng kumpletong IPv4/IPv6 routing, kabilang ang tunnel at IP multicast. Maaaring itakda ng user ang lahat ng uri ng function ng switch sa pamamagitan ng Web, SNMP at iba pa. L3 24+4 10Gigabit Ethernet Switch napaka-angkop para sa pagsasama-sama ng aplikasyon ng malakihang network at ang pangunahing aplikasyon ng medium at maliit na laki ng network. Detalye ng produkto Ang modelo ng produkto L3 24+4 10Gigabit Ethernet Switch Pangunahing katangian Nakapirming port 24 10/100/1000Base-T Ethernet port, 4 10G SFP+ ports Backplane bandwidth 128Gbps Packet forwarding rate 95.232Mpps Processor RISC 400MHz Kapasidad ng memorya ng 8MB 8MB ng memorya ng Flash Talahanayan ng address 16K Mga katangian ng produkto Spanning tree Support STP, RSTP, MSTP Support PVST/PVST+ VLAN Support port-based VLAN Support MAC-based VLAN Support 802.1Q na may label na VLAN Support para sa Super Vlan Support para sa Pribadong Vlan Support para sa GVRP dynamic na VLAN configuration Suporta sa QinQ at flexible QinQ Suporta para sa Voice VLAN Flow control Batay sa isang karaniwang IEEE 802.3x flow control Gamit ang IEEE 802.1Qbb priority flow control Suportahan ang CAR function Broadcast control Pinipigilan ang broadcast storm, ihinto ang pagpapadala hangga't umabot sa kritikal na punto multicast control IGMP Snooping multicast message automatic monitoring multicast routing IGMP v1/v2/v3, MLDv2 PIM-SM, OLINK&PIM-DM DVMRP (Distance Vector Multicast Routing Protocol) GMRP (multicast dynamic registration protocol) Port binding Ang bawat pangkat ng maximum na 8, habang support 128 group LACP dynamic o static polymerization Port mirroring Suporta batay sa flow classification mirroring at port mirroring Stacked Stacked 16 hard, soft stacking 32 Paggamit ng clustering techniques, na may pinag-isang sentralisadong pamamahala ng IP address para gawin ang address resource saving Pamamahala ng routing Static routing RIP v1 /v2, OSPFv2, BEIGRP (katugma sa Cisco EIGRP), BGPv4, ISIS, BGP Anti virus intelligent routing function Strategy routing Suporta batay sa IP strategy routing Ang proxy function Support Proxy ARP, DNS Proxy Redundancy backup Suporta para sa VRRP, HSRP Hot Standby Router Protocol Mga Katangian ng DHCP DHCP Server, DHCP Client at suporta DHCP relay Function ng NAT Suportahan ang static o dynamic NAT address translation function Mga katangiang pangkaligtasan IEEE 802.1x port certification, PKI certification Pag-andar ng Port Security (Port Security) Suporta sa hardware para sa IP ACL ACL ACL, MAC, Vlan Suporta sa hardware para sa user account na nakabatay sa port IP+MAC+Vlan ID+ user account ng iba't ibang salik na pinagsama-sama para magbigkis Suporta sa IP Source Guard Suporta sa WEB interface user authentication Remote RADIUS , TACACS+ certification Pamamahala ng pag-uuri ng user at proteksyon ng password Net shield technology Teknolohiya ng kontrol sa kaligtasan Listahan ng kontrol ng patakaran Kalidad ng serbisyo IEEE 802.1Qau congestion mechanism Ang bawat port 8 ay nagpapadala ng queue mapping 802.1p 8 priority WRED, WFQ, SP at FIFO queue scheduling algorithm Best-Effort Service Differentiated Service Strict Priority Weighted Round Robin First come first serve TOS para markahan ang RTS Network management SNMP v1/v2/v3 RMON (1,2,3,9 grupo) Telnet WEB interface Suporta para sa pamamahala ng kumpol Suporta sa SSH Suporta para sa PDP (katugma sa Cisco CDP.) Upang suportahan ang fan, temperatura, system log, hierarchical alarm Mga pisikal na katangian Laki ng hitsura 440x230x44(mm) Power characteristic AC 110-240V adaptive, 47-63Hz, 1A/230V, RPS power hot backup Power 80W Indicator lamp Power indicator, indikasyon ng system, pagkonekta / mga tagubilin sa transceiver Ang kahalumigmigan sa kapaligiran / temperatura 0-50 ℃ operasyon, -40-70 ℃ pangangalaga, 0-90% walang condensation
Pagtatanong
Detalye