- Pang-industriyang Ethernet Switch
- Fiber Media Converter
- Fiber Ethernet Switch
- Power Over Ethernet
- SFP Module
- AOC/DAC Cable
- Fiber Ethernet Server Adapter
- Fiber Video Converter
- Converter ng Interface
- PDH-SDH Multiplexer
- Telepono Fiber Video Converter
- FTTH
- Mga Rack at Enclosure
- HDMI/VGA Extender
- HDMI Splitter
- WDM
- OTN/WDM Optical Transmission Network System
0102030405

01
Magandang De-kalidad na Industrial Ethernet Switch - 2*10G Fiber Port+24*1000Base-X, Pinamamahalaang Industrial Ethernet Switch JHA-MIGS...
2016-01-08
2*10G Fiber Port+24*1000Base-X, Pinamamahalaang Industrial Ethernet Switch JHA-MIGS24W2-1U Pangkalahatang-ideya ng JHA-MIGS24W2-1U na may 2*10G fiber, 24*1000M fiber port, pamamahala ng pang-industriyang Ethernet switch, na nagbibigay ng mahusay na pang-industriya na kalidad tulad ng mataas/mababang temperatura, proteksyon ng kidlat, atbp., sa pamamagitan ng disenyo ng fanless cooling circuit, malawak na hanay ng kapaligiran sa pagtatrabaho temperatura, mataas na antas ng proteksyon at iba pang mga teknolohiya. Bukod pa rito, ang iba't ibang mayayamang protocol, tulad ng pinagsama-samang paglipat at seguridad, ay sumusuporta sa pampublikong Ethernet multi-ring protection technology (ERPS), na lubos na nagpapabuti sa flexibility ng network at nagpapahusay sa pagiging maaasahan at seguridad ng mga industriyal na network. Maaari din nitong matugunan ang mga kinakailangan sa deployment ng rail transit, ligtas na lungsod, matalinong transportasyon, panlabas na pagsubaybay at iba pang malupit na kapaligiran. Mga Tampok Power input: DC 36~75V AC 100~240V 50/60Hz Operate temperature:-40℃ ~ 75℃ Shell:IP40 na antas ng proteksyon,walang fanless na disenyo Ulat ng pagsubok:CCC/CE/FCC/RoHS Anti-static:8KV-15KV MTBF :100000hours Mga Parameter Provider Mode Ports Nakapirming port 2*10G Base-X, 24*1000 Base-X Management Port Support console Power interface Phoenix terminal, dual power supply redundancy LED Indicators PWR,Link/ACT LED Cable Uri at Distansya ng Transmission Twisted-pair 0-100m(CAT5e,CAT6) Monomode optical fiber 20/40/ 60/80/100KM Multimode optical fiber 550m Network Topology Ring topology Support Star topology Support Bus topology Support Tree Topology Support Hybrid topology Support Electrical Specifications Input voltage DC36-75V/AC 100-240V 50-60HZ Kabuuang Power consumption
Pagtatanong
Detalye

01
Magandang Kalidad ng SFP Module - 40G QSFP+ IR4, 2km 1310nm SFP Transceiver JHA-QC02 - JHA
2016-01-08
Mga Tampok: ◊ Hanggang sa 11.2Gbps bawat channel bandwidth ◊ Pinagsama-samang bandwidth ng > 40Gbps ◊ Duplex LC connector ◊ Sumusunod sa 40G Ethernet IEEE802.3ba at 40GBASE-SR4 at 40GBASE-IR4Standard ◊ QSFP MSA compliant sa ◊040m Ang maximum na haba ng link sa ◊040m link sa OM4 ◊ 4 CWDM lane na MUX/DEMUX na disenyo ◊ Sumusunod sa QDR/DDR Infiniband data rate ◊ Single +3.3V power supply operating ◊ Built-in digital diagnostic functions ◊ Temperatura range 0°C hanggang 70°C ◊ RoHS Compliant Part Applications: ◊ Rack to rack ◊ Mga sentro ng data Mga Switch at Router ◊ Mga Metro network ◊ Mga Switch at Router ◊ 40G Ethernet Links Paglalarawan: Ang JHA-QC02 ay isang transceiver module na idinisenyo para sa 2km(SMF) 160m(MMF)optical communication applications. Ang disenyo ay sumusunod sa 40GBASE-SR4 at 40GBASE-IR4 ng IEEE P802.3ba standard. Ang module ay nagko-convert ng 4 na input channel (ch) ng 10Gb/s electrical data sa 4 CWDM optical signal, at pina-multiply ang mga ito sa isang channel para sa 40Gb/s optical transmission. Sa kabaligtaran, sa bahagi ng receiver, ang module ay optically de-multiplexes isang 40Gb/s input sa 4 CWDM channels signal, at convert ang mga ito sa 4 channel output electrical data. Ang mga gitnang wavelength ng 4 na CWDM channel ay 1271, 1291, 1311 at 1331 nm bilang mga miyembro ng CWDM wavelength grid na tinukoy sa ITU-T G694.2. Naglalaman ito ng duplex LC connector para sa optical interface at isang 38-pin connector para sa electrical interface. Upang mabawasan ang optical dispersion sa long-haul system, kailangang ilapat ang multimode fiber (MMF) sa module na ito. Ang produkto ay dinisenyo na may form factor, optical/electrical connection at digital diagnostic interface ayon sa QSFP Multi-Source Agreement (MSA). Ito ay idinisenyo upang matugunan ang pinakamahirap na panlabas na kondisyon ng pagpapatakbo kabilang ang temperatura, halumigmig at pagkagambala ng EMI. Ang module ay gumagana mula sa isang +3.3V power supply at ang mga global control signal ng LVCMOS/LVTTL gaya ng Module Present, Reset, Interrupt at Low Power Mode ay available kasama ng mga module. Available ang 2-wire serial interface para magpadala at tumanggap ng mas kumplikadong mga control signal at makakuha ng digital diagnostic information. Maaaring matugunan ang mga indibidwal na channel at maaaring isara ang mga hindi ginagamit na channel para sa maximum na flexibility ng disenyo. Ang TQP10 ay dinisenyo na may form factor, optical/electrical na koneksyon at digital diagnostic interface ayon sa QSFP Multi-Source Agreement (MSA). Ito ay idinisenyo upang matugunan ang pinakamahirap na panlabas na kondisyon ng pagpapatakbo kabilang ang temperatura, halumigmig at pagkagambala ng EMI. Nag-aalok ang module ng napakataas na functionality at feature integration, na naa-access sa pamamagitan ng two-wire serial interface. • Simbolo ng Parameter ng Parameter ng Ganap na Pinakamataas na Rating Min. Karaniwang Max. Temperatura ng Imbakan ng Yunit TS -40 +85 °C Supply Voltage VCCT, R -0.5 4 V Relative Humidity RH 0 85 % • Inirerekomendang Operating Environment: Parameter Symbol Min. Karaniwang Max. Temperatura ng pagpapatakbo ng Unit Case TC 0 +70 °C Supply Voltage VCCT, R +3.13 3.3 +3.47 V Kasalukuyang ICC 1000 mA Power Dissipation PD 3.5 W • Mga Katangian ng Elektrisidad (TOP = 0 hanggang 70 °C, VCC = 3.13 hanggang 3.47 Volts Parameter Simbolo Min Typ Max Unit Note Rate ng Data bawat Channel - 10.3125 11.2 Gbps Power Consumption - 2.5 3.5 W Supply Current Icc 0.75 1.0 A Control I/O Voltage-High VIH 2.0 Vcc V Control I/O Voltage-Mababang VIL 0 0.7 V Inter-Channel Skew TSK 150L Tagal ng RESET De US - igiit ang oras 100 ms Power On Time 100 ms Transmitter Single Ended Output Voltage Tolerance 0.3 4 V 1 Common mode Voltage Tolerance 15 mV Transmit Input Diff Voltage VI 150 1200 mV Transmit Input Diff Impedance ZIN 85 100 115 Data Dependent UI Output Voltage Tolerance 0.3 4 V Rx Output Diff Voltage Vo 370 600 950 mV Rx Output Rise and Fall Voltage Tr/Tf 35 ps 1 Total Jitter TJ 0.3 UI Note: 20~80% • Optical Parameters(TOP = 0 to 0. VCC = 3.0 hanggang 3.6 Volts) Simbolo ng Parameter Min Typ Max Unit Ref. Transmitter Wavelength Assignment L0 1264.5 1271 1277.5 nm L1 1284.5 1291 1297.5 nm L2 1304.5 1311 1317.5 nm L3 1324.5 1331 1284.5 1291 1297.5 nm L2 1304.5 1311 1317.5 nm L3 1324.5 1331 1331 1297.5 nm L2 1304.5 1311 1317.5 nm L3 1324.5 1331 1331 1337.5 Average Launch Power PT - - 8.3 dBm Average Launch Power, bawat Lane -7 - 8 dBm Pagkakaiba sa Launch Power sa pagitan ng alinmang dalawang Lanes (OMA) - - 6.5 dB Optical Modulation Amplitude, bawat Lane OMA -4 +3.5 dBm Launch Power sa OMA minus Transmitter at Dispersion Penalty (TDP), bawat Lane -4.8 - dBm TDP, bawat Lane TDP 2.3 dB Extinction Ratio ER 3.5 - - dB Transmitter Eye Mask Definition {X1, X2, X3, Y1, Y2, Y3} {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} Optical Return Loss Tolerance - 2 na dB Average Power OFF Transmitter, bawat Lane Poff -30 dBm Relative Intensity Noise Rin -128 dB/HZ 1 Optical Return Loss Tolerance - - 12 dB Receiver Damage Threshold THd 3.3 dBm 1 Average na Power sa Receiver Input, bawat Lane R -10 0 dBm Receive Electrical 3 dB upper, Cut off Electrical 3 dB upper bawat Lane 12.3 GHz RSSI Accuracy -2 2 dB Receiver Reflectance Rrx -26 dB Receiver Power (OMA), bawat Lane - - 3.5 dBm Receive Electrical 3 dB upper Cutoff Frequency, bawat Lane 12.3 GHz LOS De-Assert LOSD -15 dBm LOS Assert LOSA -25 dBm LOS LOSH 0.5 dB Note 12dB Reflection • Diagnostic Monitoring Interface Ang digital diagnostics monitoring function ay available sa lahat ng QSFP+ SR4. Ang isang 2-wire serial interface ay nagbibigay ng user upang makipag-ugnayan sa module. Ang istraktura ng memorya ay ipinapakita sa daloy. Ang memory space ay nakaayos sa isang mas mababang, solong pahina, address space na 128 bytes at maramihang mga upper address space na pahina. Ang istrukturang ito ay nagbibigay-daan sa napapanahong pag-access sa mga address sa ibabang pahina, tulad ng Interrupt Flag at Monitor. Ang mas kaunting oras na mga entry sa kritikal na oras, tulad ng impormasyon ng serial ID at mga setting ng threshold, ay available sa function na Page Select. Ang interface address na ginamit ay A0xh at pangunahing ginagamit para sa oras na kritikal na data tulad ng interrupt handling upang paganahin ang isang beses na basahin para sa lahat ng data na nauugnay sa isang interrupt na sitwasyon. Pagkatapos ng interrupt, iginiit ng IntL, mababasa ng host ang flag field para matukoy ang apektadong channel at uri ng flag. Ang Page02 ay User EEPROM at ang format nito ay napagpasyahan ng user. Ang detalyadong paglalarawan ng mababang memorya at page00.page03 itaas na memorya mangyaring tingnan ang dokumentong SFF-8436. • Timing para sa Soft Control at Status Functions Parameter Symbol Max Unit Conditions Initialization Time t_init 2000 ms Oras mula sa power on1, mainit na plug o tumataas na gilid ng I-reset hanggang ang module ay ganap na gumagana2 I-reset ang Init Assert Time t_reset_init 2 μs Isang Reset ay nabuo sa pamamagitan ng isang mababang mas mahaba kaysa sa minimum na reset pulse time na nasa ResetL pin. Oras ng Handa ng Serial Bus Hardware t_serial 2000 ms Oras mula sa power on1 hanggang sa tumugon ang module sa paghahatid ng data sa pamamagitan ng 2-wire serial bus Monitor Data ReadyTime t_data 2000 ms Oras mula sa power on1 hanggang sa data na hindi handa, bit 0 ng Byte 2, deasserted at IntL asserted I-reset ang Assert Time t_reset 2000 ms Oras mula sa tumataas na gilid sa ResetL pin hanggang sa ganap na ang module functional2 LPMode Assert Time ton_LPMode 100 μs Oras mula sa assertion ng LPMode (Vin:LPMode =Vih) hanggang sa pumasok ang power consumption ng module sa mas mababang Power Level IntL Assert Time ton_IntL 200 ms Oras mula sa paglitaw ng kundisyon na nagti-trigger ng IntL hanggang Vout:IntL = Vol IntL Time toff_IntL Time 500 μs toff_IntL 500 μs Oras mula sa malinaw sa read3 na operasyon ng nauugnay na flag hanggang Vout:IntL = Voh. Kabilang dito ang mga oras ng deassert para sa Rx LOS, Tx Fault at iba pang flag bits. Rx LOS Assert Time ton_los 100 ms Oras mula Rx LOS state hanggang Rx LOS bit set at IntL asserted Flag Assert Time ton_flag 200 ms Oras mula sa paglitaw ng kundisyon na nagti-trigger ng flag hanggang sa nauugnay na flag bit set at IntL asserted Mask Assert Time ton_mask 100 ms Oras mula sa mask bit set4 hanggang sa ang nauugnay na IntL assertion ay inhibited Mask De-assert Time toff_mask 100 ms Oras mula sa mask bit na-clear4 hanggang sa nauugnay na operasyon ng IntlL ay nagpapatuloy sa ModSelL Assert Time ton_ModSelL 100 μs Oras mula sa assertion ng ModSelL hanggang tumugon ang module sa paghahatid ng data sa 2-wire serial bus na ModSelL Deassert Time toff_ModSelL 100 μs na Oras mula sa ModSelL 100 μs na Oras mula sa ModSelL 100 μs na Oras module ay hindi tumutugon sa paghahatid ng data sa ibabaw ng 2-wire serial bus Power_over-ride oPower-set Assert Time ton_Pdown 100 ms Oras mula P_Down bit set 4 hanggang module power consumption ay pumasok sa mas mababang Power Level Power_over-ride o Power-set De-assert Time toff_Pdown 300 ms Oras mula P_Down bit clear4 hanggang ang module ay fully functional3 Tandaan: 1. Ang power on ay tinukoy bilang ang instant kapag umabot ang mga boltahe ng supply at nananatili sa o higit sa minimum tinukoy na halaga. 2. Ang fully functional ay tinukoy bilang IntL asserted dahil sa data not ready bit, bit 0 byte 2 de-asserted. 3. Sinusukat mula sa bumabagsak na gilid ng orasan pagkatapos huminto ng kaunting nabasang transaksyon. 4. Sinusukat mula sa bumabagsak na gilid ng orasan pagkatapos ng stop bit ng write transaction. • Transceiver Block Diagram • Pin Assignment Diagram ng Host Board Connector Block Pin Numbers and Name • Pin Description Pin Logic Symbol Name/Description Ref. 1 GND Ground 1 2 CML-I Tx2n Transmitter Inverted Data Input 3 CML-I Tx2p Transmitter Non-Inverted Data output 4 GND Ground 1 5 CML-I Tx4n Transmitter Inverted Data Output 6 CML-I Tx4p Transmitter Non-Inverted Data Output 7 Ground 1 8 LVTTL-I ModSelL Module Piliin ang 9 LVTTL-I ResetL Module Reset 10 VccRx +3.3V Power Supply Receiver 2 11 LVCMOS-I/O SCL 2-Wire Serial Interface Clock 12 LVCMOS-I/O SDA 2-Wire Serial Interface Data 13 GND Ground 1 14 CML- O Rx3p Receiver Inverted Data Output 15 CML-O Rx3n Receiver Non-Inverted Data Output 16 GND Ground 1 17 CML-O Rx1p Receiver Inverted Data Output 18 CML-O Rx1n Receiver Non-Inverted Data Output 19 GND Ground 1 20 GND Ground 1 21 CML-O Rx1n Receiver Non-Inverted Data Output 19 GND Ground 1 20 GND Ground 1 21 CML-O Receiver Invert Data Invert2n2 -O Rx2p Receiver Non-Inverted Data Output 23 GND Ground 1 24 CML-O Rx4n Receiver Inverted Data Output 25 CML-O Rx4p Receiver Non-Inverted Data Output 26 GND Ground 1 27 LVTTL-O ModPrsL LVT Interrupted na Module 27 LVTTL-O ModPrsL LVT na Interrupt 28 LVTTL 28 +3.3V Power Supply Transmitter 2 30 Vcc1 +3.3V Power Supply 2 31 LVTTL-I LPMode Low Power Mode 32 GND Ground 1 33 CML-I Tx3p Transmitter Inverted Data Output 34 CML-I Tx3n Transmitter Non-Inverted GND Data Output 35 1 36 CML-I Tx1p Transmitter Inverted Data Output 37 CML-I Tx1n Transmitter Non-Inverted Data Output 38 GND Ground 1 Mga Tala: Ang GND ay ang simbolo para sa single at supply(power) na karaniwan para sa QSFP modules, Lahat ay karaniwan sa loob ng QSFP module at lahat ng module voltages ay tinutukoy sa ang potensyal na ito kung hindi man ay nabanggit. Direktang ikonekta ang mga ito sa host board signal common ground plane. Naka-disable ang laser output sa TDIS >2.0V o bukas, naka-enable sa TDIS
Pagtatanong
Detalye
























