8 10/100/1000TX Futhi 8 1000X SFP Slot |I-Industrial Ethernet Switch ephethwe i-JHA-MIGS808H

Incazelo emfushane:

* Sekela i-8 1000Base-X SFP slot kanye ne-8 10/100/1000Base-T(X) Ethernet port ephethwe i-industrial fiber switch;

* Usekelo lwe-G.8032(ERPS), IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.3ab, IEEE802.1p, IEEE802.1x. IEEE802.3z. IPv6 kuqala.

* Ukusekela i-CLI, i-SNMP, ukuphathwa kwe-WEB, ukuphathwa komugqa womyalo we-Console/Telnet kanye ne-syslog, kusetshenziswa ubuchwepheshe benethiwekhi yendandatho yokuzithuthukisa, isikhathi sokutakula <20ms.

* Amandla e-DC10-55V okubuyisela emuva, ukuvikela ukuhlehla kwe-polarity.

* IP40 elinganiselwe nge-aluminium alloy izindlu, i-DIN-Rail ifakwe.

* Iwaranti yeminyaka engu-5.


Uhlolojikelele

Isici

Ukucaciswa

Ubukhulu

Oda Ulwazi

Landa

 

Isingeniso

I-JHA-MIGS808H iwukusebenza okuphezulu, ukushintshwa kwe-Ethernet yezimboni ephethwe engabizi kakhulu.Iswishi inikeza imbobo ye-Ethernet engu-8 10/100/1000Base-T(X) kanye nembobo ye-8 1000Base-X SFP.Ukusetshenziswa kobuchwepheshe be-Ring (i-network fault recovery <20ms) umsebenzisi angakwazi ukusetha kalula inethiwekhi yendandatho engasasebenzi ukuze akhulise ukwethembeka kwenethiwekhi, futhi isekela i-WEB, i-CLI, i-Telnet/serial console, i-Windows utility, kanye nokuphathwa kwe-SNMP yezindlela ezihlukahlukene. , izici ezicebile ze-QoS zokulawula nokuphathwa kwethrafikhi yedatha, iphrothokholi yokusekela indandatho, i-RSTP ne-STP Ethernet ukwesekwa kwe-dundancy esekelwe echwebeni i-VLAN, i-IEEE 802.1Q VLAN kanye nephrothokholi ye-GVRP.Umkhiqizo futhi ukwakhiwa kwezimboni, futhi ungasetshenziswa kabanzi ku-PIS yezimoto, i-CCTV, izinhlelo zokubhekwa kwevidiyo, uhlelo lokulawula isitimela, kodwa futhi usebenza kunoma yikuphi ukushaqeka kokudlidliza, izidingo zokuhambisana kwe-EMC zezicelo zezimboni ezinokhahlo, zingahlangabezana nezidingo ezahlukahlukene zesizinda sezimboni ukuze ukuzuza ukuthembeka okuphezulu.

Ukucaciswa

Isixhumi esibonakalayo
I-Fiber Port 8*100/1000Base-X SFP
Imbobo ye-Ethernet 8*10/100/1000 Isisekelo-T
Phatha Imbobo 1*RJ45 Console port
Isixhumi samandla Itheminali ye-3P Phoenix, ukuphela kokunikezwa kwamandla okubili
Isibonisi se-LED I-PWR (eluhlaza);

Inkomba yesistimu:SYS(okuluhlaza);

Inkomba yembobo yenethiwekhi:ophuzi(1000 noma i-POE) Okuluhlaza (Isixhumanisi)Uhlobo lwekhebula nebangaIkhebula elisontiwe0-100m (CAT5e, CAT6)I-fiber yemodi eyodwa20/40/60/80/100KMI-Multimode fiber550m/2KMI-Optical fiber interfaceI-LC/SCI-topology yenethiwekhi nesikaliI-topology yokukhalaUkusekelaI-topology yenkanyeziUkusekelaI-topology yebhasiUkusekelaI-topology yesihlahlaUkusekelaI-Hybrid topologyUkusekelaIzici zikagesiI-voltage yokufakaI-DC10-58V/AC 100-240V 50-60HZUkusetshenziswa kwamandlaUkulayisha okugcwele okungewona we-POE (Amandla Aphelele) <10W

Umthwalo ogcwele we-POE <132WI-PoESupport(Ongakukhetha)Amachweba we-PoE1-8Iphrothokholi ye-PoE802.3af, 802.3atUmsebenzi we-PoE pin1,2,3,6Imodi yokuphatha ye-PoEUkusekelaIzimpawu ze-L2Umthamo wokushintshanisa40GIzinga lokudlulisela iphakethe23.8MppsIthebula lekheli le-MAC16KUkusekelwa kwe-VLAN kanye nenaniSekela i-4KBika ibhafa8MUkulibaziseka kokudlulisela<10usIzici zemboboI-cross-connect kanye ne-direct-adaptiveUkulawula ukugelezaUkusekela

Ukusekelwa kohlaka lwe-Jumbo Sekela 10Kbytes
I-Spanning Tree Protocol Sekela i-STP/RSTP/MSTP
Iphrothokholi yenethiwekhi yokukhalisa Sekela i-ERPS
Ukuhlanganisa isixhumanisi Sekela amaqembu ayi-12
Ukusakaza okuningi Sekela i-IGMP Snooping
Isibuko sembobo Ukusekela
Ukucindezelwa kwesiphepho Ukusekela
Izibalo zethrafikhi yasechwebeni Ukusekela
Uhlelo lokugeleza kwembobo Ukusekela
QINQ Ukusekela
 

 

 

 

UkuvikelwaIgobolondo: Ukuvikelwa kwe-IP40, izindlu ze-aluminium alloy

I-IEC 61000-4-5 Ileveli 3 (4KV/2KV) (8/20us)

I-IEC 61000-4-5 Ileveli 3 (6KV/2KV) (10/700us)

I-IEC 61000-4-3 Ileveli 3 (10V/m)

I-IEC 61000-4-4 Ileveli 3 (1V/2V)

I-IEC 61000-4-6 Ileveli 3 (10V/m)

I-IEC 61000-4-8 Level4 (30A/m)

I-IEC 61000-4-11 Level3 (10V)

I-EMI CLASS A

I-IEC 61000-4-2 Ileveli 4 (15KV/30KV)

Ukuwa kwamahhala 0.5mIsevisi ye-ConvergenceI-ACLSekela ama-ACL angama-500;

Ukusekela IP standard ACL;

Sekela i-MAC enwetshiwe ye-ACL;

Ukusekela IP enwetshiwe ACL;QoSSekela ukumaka kabusha kwe-QoS nokubeka imephu okubalulekile;

Ukusekela i-SP, ukuhlela ulayini we-WRR;

Ukusekela umkhawulo wejubane lokungena kanye nomkhawulo wejubane lokuphuma;

Ukusekela ukugeleza okusekelwe ku-QoSUmsebenzi wokuphathaUmugqa womyaloUkusekelaImbobo ye-serial yokuphathaUkusekelaI-TelnetUkusekelaUkuphathwa kweWEBHUkusekelaI-SNMPSekela i-SNMPv1/v2cUkuphathwa komsebenzisiUkusekelaIlogi yesistimuUkusekelaUkuthuthukiswa kwefayelaUkusekelaUkuthuthukiswa kwe-FirmwareUkusekelaSFP module DDMUkusekelaIzimo zemvelo

Izinga lokushisa lokusebenza -40℃~+85℃
Isitoreji/izinga lokushisa lokuthutha -40℃~+85℃
Umswakama ohlobene 5%~95% ayikusekeli ukujiya (ukungafinyezi)
Indlela yokupholisa Ayikho idizayini yabalandeli, ukunqanyulwa kokushisa kwemvelo
MTBF Amahora angu-100,000
Isakhiwo semishini
Usayizi 181X146X47mm
Indlela yokufaka Ukufakwa kwe-DIN Rail
Isisindo 1.5KG

Ubukhulu

I-JHA-MIGS808H

Oda Ulwazi

Imodeli No.

Incazelo Yezimpahla

I-JHA-MIGS808H

I-Industrial Ethernet Switch, 8 1000Base-X SFP Slot kanye ne-8 10/100/1000Base-T(X), DIN-Rail, DC10-58V, -40-85°C Izinga Lokushisa Lokusebenza

I-JHA-MIGS808HP

I-Industrial PoE Switch, 8 10/100/1000Base-T(X) PoE/PoE+ kanye ne-8 1000Base-X SFP Slot, DIN-Rail, DC48-58V, -40-85°C Izinga Lokushisa Lokusebenza

Ukunikezwa kwamandla kagesi:I-DC24V DIN-Rail Power Supply noma i-adaptha yamandla ingokuzithandela.

I-DC48V DIN-Rail Power Supply noma i-adaptha yamandla ingokuzithandela.(PoE)

 


  • Okwedlule:
  • Olandelayo:

  • Isici

    *Sekela i-8 1000Base-X SFP slot kanye nembobo ye-Ethernet engu-8 10/100/1000Base-T(X).

    *Ukusekela i-G.8032(ERPS), IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.3ab, IEEE802.1p, IEEE802.0G2, IEEE802.0G2. IPv6 kuqala.

    *Sekela i-CLI, i-SNMP, ukuphathwa kwe-WEB, i-Console/Telnet yokulawulwa komugqa womyalo kanye ne-syslog, kusetshenziswa ubuchwepheshe benethiwekhi yeringi obuzithuthukisele, isikhathi sokutakula <20ms.

    *Amandla e-DC10-58V okubuyiselwa emuva, ukuvikela ukuhlehla kwe-polarity.

    *Idizayini yebanga lesi-4 yezimboni, izinga lokushisa elisebenzayo -40-85°C.

    *IP40 elinganiselwe ngezindlu ze-aluminium alloy, i-DIN-Rail ifakwe.

    Ukucaciswa

    Isixhumi esibonakalayo

    I-Fiber Port

    8*100/1000Base-X SFP

    Imbobo ye-Ethernet

    8*10/100/1000 Isisekelo-T

    Phatha Imbobo

    1*RJ45 Console port

    Isixhumi samandla

    Itheminali ye-3P Phoenix, ukuphela kokunikezwa kwamandla okubili

    Isibonisi se-LED

    I-PWR (eluhlaza);

    Inkomba yesistimu:SYS(okuluhlaza);

    Inkomba yembobo yenethiwekhi:ophuzi(1000 noma i-POE) Okuluhlaza (Isixhumanisi)

    Uhlobo lwekhebula nebanga

    Ikhebula elisontiwe

    0-100m (CAT5e, CAT6)

    I-fiber yemodi eyodwa

    20/40/60/80/100KM

    I-Multimode fiber

    550m/2KM

    I-Optical fiber interface

    I-LC/SC

    I-topology yenethiwekhi nesikali

    I-topology yokukhala

    Ukusekela

    I-topology yenkanyezi

    Ukusekela

    I-topology yebhasi

    Ukusekela

    I-topology yesihlahla

    Ukusekela

    I-Hybrid topology

    Ukusekela

    Izici zikagesi

    I-voltage yokufaka

    I-DC10-58V/AC 100-240V 50-60HZ

    Ukusetshenziswa kwamandla

    Ukulayisha okugcwele okungewona we-POE (Amandla Aphelele) <10W

    Umthwalo ogcwele we-POE <132W

    I-PoESupport(Ongakukhetha)

    Amachweba we-PoE

    1-8

    Iphrothokholi ye-PoE

    802.3af, 802.3at

    Umsebenzi we-PoE pin

    1,2,3,6

    Imodi yokuphatha ye-PoE

    Ukusekela

    Izimpawu ze-L2

    Umthamo wokushintshanisa

    40G

    Izinga lokudlulisela iphakethe

    23.8Mpps

    Ithebula lekheli le-MAC

    16K

    Ukusekelwa kwe-VLAN kanye nenani

    Sekela i-4K

    Bika ibhafa

    8M

    Ukulibaziseka kokudlulisela

    <10us

    Izici zembobo

    I-cross-connect kanye ne-direct-adaptive

    Ukulawula ukugeleza

    Ukusekela

    Ukusekelwa kohlaka lwe-Jumbo

    Sekela 10Kbytes

    I-Spanning Tree Protocol

    Sekela i-STP/RSTP/MSTP

    Iphrothokholi yenethiwekhi yokukhalisa

    Sekela i-ERPS

    Ukuhlanganisa isixhumanisi

    Sekela amaqembu ayi-12

    Ukusakaza okuningi

    Sekela i-IGMP Snooping

    Isibuko sembobo

    Ukusekela

    Ukucindezelwa kwesiphepho

    Ukusekela

    Izibalo zethrafikhi yasechwebeni

    Ukusekela

    Uhlelo lokugeleza kwembobo

    Ukusekela

    Umzila ongashintshi

    Ukusekela

    QINQ

    Ukusekela

     

     

     

     

    Ukuvikelwa

    Igobolondo: Ukuvikelwa kwe-IP40, izindlu ze-aluminium alloy

    I-IEC 61000-4-5 Ileveli 3 (4KV/2KV) (8/20us)

    I-IEC 61000-4-5 Ileveli 3 (6KV/2KV) (10/700us)

    I-IEC 61000-4-3 Ileveli 3 (10V/m)

    I-IEC 61000-4-4 Ileveli 3 (1V/2V)

    I-IEC 61000-4-6 Ileveli 3 (10V/m)

    I-IEC 61000-4-8 Level4 (30A/m)

    I-IEC 61000-4-11 Level3 (10V)

    I-EMI CLASS A

    I-IEC 61000-4-2 Ileveli 4 (15KV/30KV)

    Ukuwa kwamahhala 0.5m

    Isevisi ye-Convergence

    I-ACL

    Sekela ama-ACL angama-500;

    Ukusekela IP standard ACL;

    Sekela i-MAC enwetshiwe ye-ACL;

    Ukusekela IP enwetshiwe ACL;

    QoS

    Sekela ukumaka kabusha kwe-QoS nokubeka imephu okubalulekile;

    Ukusekela i-SP, ukuhlela ulayini we-WRR;

    Ukusekela umkhawulo wejubane lokungena kanye nomkhawulo wejubane lokuphuma;

    Ukusekela ukugeleza okusekelwe ku-QoS

    Umsebenzi wokuphatha

    Umugqa womyalo

    Ukusekela

    Imbobo ye-serial yokuphatha

    Ukusekela

    I-Telnet

    Ukusekela

    Ukuphathwa kweWEBH

    Ukusekela

    I-SNMP

    Sekela i-SNMPv1/v2c

    Ukuphathwa komsebenzisi

    Ukusekela

    Ilogi yesistimu

    Ukusekela

    Ukuthuthukiswa kwefayela

    Ukusekela

    Ukuthuthukiswa kwe-Firmware

    Ukusekela

    SFP module DDM

    Ukusekela

    Izimo zemvelo

    Izinga lokushisa lokusebenza

    -40℃~+85℃

    Isitoreji/izinga lokushisa lokuthutha

    -40℃~+85℃

    Umswakama ohlobene

    5%~95% ayikusekeli ukujiya (ukungafinyezi)

    Indlela yokupholisa

    Ayikho idizayini yabalandeli, ukunqanyulwa kokushisa kwemvelo

    MTBF

    Amahora angu-100,000

    Isakhiwo semishini

    Usayizi

    181X146X47mm

    Indlela yokufaka

    Ukufakwa kwe-DIN Rail

    Isisindo

    1.5KG

    Ubukhulu

    A-9

    Oda Ulwazi

    Imodeli No.

    Incazelo Yezimpahla

    I-JHA-MIGS808H

    I-Industrial Ethernet Switch, 8 1000Base-X SFP Slot kanye ne-8 10/100/1000Base-T(X), DIN-Rail, DC10-58V, -40-85°C Izinga Lokushisa Lokusebenza

    I-JHA-MIGS808HP

    I-Industrial PoE Switch, 8 10/100/1000Base-T(X) PoE/PoE+ kanye ne-8 1000Base-X SFP Slot, DIN-Rail, DC48-58V, -40-85°C Izinga Lokushisa Lokusebenza

    Ukunikezwa kwamandla kagesi:I-DC24V DIN-Rail Power Supply noma i-adaptha yamandla ingokuzithandela.

    I-DC48V DIN-Rail Power Supply noma i-adaptha yamandla ingokuzithandela.(PoE)

  • pdf
    Idatha ye-JHA-MIGS808H
    pdf
  • Bhala umyalezo wakho lapha futhi usithumelele wona