- Ngalih Ethernet industri
- Konverter Media Serat
- Serat Ethernet Ngalih
- Power liwat Ethernet
- Modul SFP
- Kabel AOC/DAC
- Serat Ethernet Server Adaptor
- Serat Video Converter
- Konverter Antarmuka
- PDH-SDH Multiplexer
- Telpon Serat Video Converter
- FTTH
- Rak & Enclosures
- HDMI/VGA Extender
- HDMI Splitter
- WDM
- Sistem Jaringan Transmisi Optik OTN/WDM
0102030405

01
Grosir China Glc-T Quotes Produsen - 10G BASE-T Tembaga SFP + Transceiver JHA3901G - JHA
2016-01-08
Fitur: ◊ Ndhukung 10Gbase-T / 5Gbase-T / 2.5Gbase-T / 1000base-T ◊ Hot-pluggable SFP footprint ◊ Compact RJ-45 konektor perakitan ◊ RoHS cecek lan timbal-free ◊ Tunggal + 3.3V power supply ◊ 10 Gigabit Ethernet liwat kabel Cat 6a ◊ Suhu Operasi Sekitar: 0°C nganti +70°C Aplikasi: ◊ 10G Ethernet liwat kabel Cat 5 ◊ Ngalih / Router kanggo Ngalih / Link Router ◊ I / O kacepetan dhuwur kanggo file severs Katrangan: JHA3901G SFP + -10GBASE-T Tembaga Bentuk Cilik Pluggable (SFP) transceiver adhedhasar SFP Multi Source Perjanjian (MSA). Padha kompatibel karo standar 10Gbase-T / 5Gbase-T / 2.5Gbase-T / 1000base-T kaya sing kasebut ing IEEE Std 802.3. SFP + -10GBASE-T nggunakake SFP kang RX_LOS (kudu ditarik munggah ing inang) pin kanggo pratondo link. Yen narik munggah utawa mbukak pin TX_DISABLE SFP, PHY IC bakal direset. • SFP kanggo Host Konektor Pin Out Pin Symbol Jeneng / Description Ref. 1 VEET Transmitter Ground (Umum karo Receiver Ground) 1 2 TFAULT Transmitter Fault. Ora didhukung. 3 TDIS Transmitter Pateni. Output laser dipatèni ing dhuwur utawa mbukak. 2 4 MOD_DEF (2) Definition modul 2. baris data kanggo Serial ID. 3 5 MOD_DEF (1) Definition modul 1. baris jam kanggo ID Serial. 3 6 MOD_DEF(0) Definition Modul 0. Grounded ing modul. 3 7 Rate Pilih Ora ana sambungan sing dibutuhake 8 LOS Dhuwur nuduhake ora ana kasambung. kurang nuduhake disambung. 4 9 VEER Receiver Ground (Umum karo Transmitter Ground) 1 10 VEER Receiver Ground (Umum karo Transmitter Ground) 1 11 VEER Receiver Ground (Umum karo Transmitter Ground) 1 12 RD- Receiver Inverted DATA metu. AC Coupled 13 RD + Receiver Non-kuwalik DATA metu. AC Coupled 14 VEER Receiver Ground (Umum karo Transmitter Ground) 1 15 VCCR Receiver Power Supply 16 VCCT Transmitter Power Supply 17 VEET Transmitter Ground (Umum karo Receiver Ground) 1 18 TD + Transmitter Non-Kuwalik DATA ing AC Coupled. 19 TD- Transmitter Inverted DATA ing AC Coupled. 20 VEET Transmitter Ground (Umum karo Receiver Ground) 1 Cathetan: 1. Circuit lemah disambungake menyang chassis lemah 2. PHY dipatèni ing TDIS> 2.0V utawa mbukak, aktif ing TDIS
Inquiry
Rincian

01
Daftar Harga Pabrik Saklar Industri Grosir China - 4*10G Fiber Port+8*1000M Combo+16*10/100/1000B...
2016-01-08
4*10G Fiber Port+8*1000M Combo+16*10/100/1000Base-T, Managed Industrial Ethernet Switch JHA-MIGS1600C08W4-1U Gambaran Umum JHA-MIGS1600C08W4-1U dengan 4*10GBase-X, 8*1000M 16 * 10/100/1000Base-T, manajemen switch Ethernet industri, nyedhiyakake kualitas industri sing apik kayata tahan suhu dhuwur / kurang, proteksi kilat, lan liya-liyane, liwat desain sirkuit pendinginan tanpa kipas, suhu lingkungan kerja sing amba, bahan proteksi dhuwur lan teknologi liyane. Kejabi, macem-macem protokol sugih, kayata ngoper terpadu lan keamanan, ndhukung Ethernet umum teknologi pangayoman multi-ring (ERPS), nemen nambah keluwesan jaringan lan nambah linuwih lan keamanan jaringan industri. Uga bisa nyukupi syarat panyebaran transit rel, kutha sing aman, transportasi cerdas, pemantauan ruangan lan lingkungan sing angel. Fitur Input daya: DC 36~75V AC 100~240V 50/60Hz Suhu operasi:-40 ℃ ~ 75 ℃ Shell: Tingkat perlindungan IP40, desain tanpa kipas Laporan Tes: CCC/CE/FCC/RoHS Anti-statis: 8KV-15KV MTBF :100000jam Parameter Mode Panyedhiya Port Port tetep 4*1000 Base-X ,8*1000M combo 16*10/100/1000 Base-T Management Port Support console Power interface Terminal Phoenix, dual power supply redundansi Indikator LED PWR,Link/ACT LED Kabel Tipe & Jarak Transmisi Twisted-pair 0-100m(CAT5e, CAT6) Serat optik monomode 20/40/60/80/100KM Multimode serat optik 550m Topologi Jaringan Topologi cincin Dhukungan Topologi Bintang Dhukungan Topologi Bus Dhukungan Topologi Pohon Dhukungan Topologi Hibrid Dhukungan Spesifikasi Listrik Tegangan Input DC 36~75V/AC 100-240V 50-60HZ Total Konsumsi Daya
Inquiry
Rincian

01
Grosir China SFP-10g-Zr= Daftar Harga Produsen - 40G QSFP+ SR4, 300m MPO 850nm JHAQC01 - JHA
2016-01-08
Fitur: ◊ Compliant kanggo 40GbE XLPPI electrical specification saben IEEE 802.3ba-2010 ◊ Compliant kanggo QSFP + SFF-8436 Specification ◊ Bandwidth agrégat saka > 40Gbps ◊ Operating at 10.3125 Gbps saben electrical channel ◊ 64b/66 Compliant QSFP ◊ Compliant QSFP MSA/66 transmisi luwih saka 100m ing OM3 Multimode Fiber (MMF) lan 150m ing OM4 MMF ◊ Operasi catu daya + 3.3V Tunggal ◊ Tanpa fungsi diagnostik digital ◊ Kisaran suhu 0 ° C nganti 70 ° C ◊ RoHS Compliant Part ◊ Nggunakke serat dupleks LC standar kabel ngijini nggunakake maneh infrastruktur kabel ana Aplikasi: ◊ 40 Gigabit Ethernet interconnects ◊ Datacom / Telecom switch & router sambungan ◊ Data agregasi lan aplikasi backplane ◊ Proprietary protokol lan Kapadhetan aplikasi Description: Iku Four-Channel, Pluggable, LC Duplex, Fiber-Optic QSFP + Transceiver kanggo 40 Gigabit Ethernet Aplikasi. Transceiver iki minangka modul kinerja dhuwur kanggo komunikasi data dupleks jarak cendhak lan aplikasi interkoneksi. Iki nggabungake papat jalur data listrik ing saben arah menyang transmisi liwat kabel serat optik duplex LC tunggal. Saben jalur listrik beroperasi ing 10.3125 Gbps lan cocog karo antarmuka 40GE XLPPI. Transceiver internal multiplexs antarmuka XLPPI 4x10G dadi rong saluran listrik 20Gb / s, ngirim lan nampa saben optik liwat siji serat LC simplex nggunakake optik bi-arah. Iki nyebabake bandwidth agregat 40Gbps dadi kabel LC duplex. Iki ngidini nggunakake maneh infrastruktur kabel duplex LC sing diinstal kanggo aplikasi 40GbE. Jarak link nganti 100 m nggunakake OM3 lan 150m nggunakake serat optik OM4 didhukung. Modul iki dirancang kanggo ngoperasikake sistem serat multimode kanthi dawa gelombang nominal 850nm ing sisih siji lan 900nm ing sisih liyane. Antarmuka listrik nggunakake konektor pinggiran jinis 38 kontak QSFP +. Antarmuka optik nggunakake konektor duplex LC konvensional. Diagram Blok Transceiver • Simbol Parameter Rating Maksimum Absolute Min. Biasane Max. Suhu Panyimpenan Unit TS -40 +85 °C Tegangan Pasokan VCCT, R -0,5 4 V Kelembapan Relatif RH 0 85 % • Lingkungan Operasi sing Disaranake: Simbol Parameter Min. Biasane Max. Unit Kasus Suhu operasi TC 0 +70 °C Tegangan Pasokan VCCT, R +3.13 3.3 +3.47 V Pasokan Saiki ICC 1000 mA Dissipasi Daya PD 3.5 W • Karakteristik Listrik (TOP = 0 nganti 70 °C, VCC = 3.13 nganti 3.47 Volt Parameter Simbol Min Typ Max Unit Cathetan Tingkat Data saben Saluran - 10.3125 11.2 Gbps Konsumsi Daya - 2.5 3.5 W Pasokan Saiki Icc 0.75 1.0 A Kontrol I/O Voltage-High VIH 2.0 Vcc V Kontrol I/O Voltage-Low VIL 0 0.7 V Inter-Channel Skew TSK 150L RESET Durasi - negesake wektu 100 ms Daya On Time 100 ms Transmitter Single Ended Output Voltage Toleransi 0,3 4 V 1 Common Mode Voltage Toleransi 15 mV Transmit Input Diff Voltage VI 120 1200 mV Transmit Input Diff Impedansi ZIN 80 100 120 Input Data Jitter UI Jitter 1 Total Jitter Input Jitter TJ 0.28 UI Receiver Single Ended Output Voltage Toleransi 0.3 4 V Rx Output Diff Voltage Vo 600 800 mV Rx Output Munggah lan Mudhun Tegangan Tr/Tf 35 ps 1 Jitter Total TJ 0.7 UI Deterministik Jitter UI DJ 0.8% UI Deterministik Jitter ~ 0: 42 % UI Optical Jitter Parameter (TOP = 0 nganti 70 °C, VCC = 3,0 nganti 3,6 Volt) Simbol Parameter Min Type Max Unit Ref. Pemancar Panjang Gelombang Optik CH1 λ 832 850 868 nm Panjang Gelombang Optik CH2 λ 882 900 918 nm RMS Jembar Spektral Pm 0,5 0,65 nm Daya Optik Rata-rata saben Pavg Saluran -4 -2,5 +5,0 dBm Daya Optik Laser Mati 3 Per Channel Optical dBm 3,5 dB Intensitas Relatif Noise Rin -128 dB/HZ 1 Optical Return Loss Toleransi 12 dB Receiver Optical Center Panjang Gelombang CH1 λ 882 900 918 nm Optical Center Panjang Gelombang CH2 λ 832 850 868 nmB Input Daya Daya PMAX Receiver Maksimum +0,5 dBm Receiver Reflectance Rrx -12 dB LOS De-Assert LOSD -14 dBm LOS Assert LOSA -30 dBm LOS Hysteresis LOSH 0,5 dB Note 12dB Reflection Page02 yaiku User EEPROM lan format sing diputusake dening pangguna. Katrangan rinci babagan memori kurang lan memori ndhuwur page00.page03, deleng dokumen SFF-8436. • Wektu kanggo Kontrol Lembut lan Fungsi Status Simbol Parameter Maks Kondisi Unit Wektu Initialization t_init 2000 ms Wektu saka daya on1, plug panas utawa munggah pinggiran Reset nganti modul wis kebak fungsi2 Reset Init Assert Time t_reset_init 2 μs A Reset digawe dening kurang tingkat maneh saka wektu pulsa reset minimal saiki ing pin ResetL. Serial Bus Hardware Wektu Siap t_serial 2000 ms Wektu saka daya on1 nganti modul nanggapi transmisi data liwat 2-kabel serial bus Monitor Data ReadyTime t_data 2000 ms Wektu saka daya on1 kanggo data ora siap, bit 0 saka Byte 2, deasserted lan IntL ditegesake Reset Assert Time t_reset 2000 ms Wektu saka munggah ing pin ResetL nganti modul kebak functional2 LPMode Assert Time ton_LPMode 100 μs Wektu saka penegasan saka LPMode (Vin:LPMode =Vih) nganti konsumsi daya modul mlebu Tingkat Daya IntL Assert Time sing luwih murah ton_IntL 200 ms Wektu saka kedadeyan kondisi micu IntL nganti Vout:IntL = Vol IntL Deassert Time 500 μs toff_IntL 500 μs Wektu saka clear on read3 operasi gendera sing gegandhengan nganti Vout:IntL = Voh. Iki kalebu kaping deassert kanggo Rx LOS, Tx Fault lan bit flag liyane. Rx LOS Assert Time ton_los 100 ms Wektu saka negara Rx LOS menyang Rx LOS bit set lan IntL ditegesake Flag Assert Time ton_flag 200 ms Wektu saka kedadeyan kondisi pemicu gendera menyang set flag bit sing gegandhengan lan IntL negesake Mask Assert Time ton_mask 100 ms Wektu saka topeng bit set4 nganti pratelan IntL sing digandhengake dicegah Mask De-assert Time toff_mask 100 ms Wektu saka bit mask dibusak4 nganti operasi IntlL sing gegandhengan diterusake ModSelL Assert Time ton_ModSelL 100 μs Wektu saka pernyataan ModSelL nganti modul nanggapi transmisi data liwat bus serial 2-kabel ModSelL Deassert Time toff_ModSelL 100 μs Wektu saka ModSelL 100 μs Wektu saka ModSelL modul ora nanggepi transmisi data liwat Bus serial 2 kabel Power_over-ride utawa Power-set Assert Time ton_Pdown 100 ms Wektu saka P_Down bit set 4 nganti modul konsumsi daya lumebu ngisor Power Level Power_over-ride utawa Power-set De-assert Time toff_Pdown 300 ms Wektu saka P_Down bit clear4 nganti modul wis kebak fungsi3 Cathetan: 1. Daya ditetepake minangka cepet nalika voltase sumber tekan lan tetep ing utawa ndhuwur minimal nilai tartamtu. 2. Fungsional kanthi lengkap ditetepake minangka IntL sing ditegesake amarga data sing durung siap, bit 0 byte 2 de-asserted. 3. Diukur saka Mudhun pinggiran jam sawise mandeg dicokot saka transaksi maca. 4. Diukur saka Mudhun pinggiran jam sawise mungkasi dicokot saka nulis transaksi. • Pin Assignment Diagram saka Papan Host Konektor Block Nomer Pin lan Jeneng • Pin Description Pin Logika Simbol Jeneng / Description Ref. 1 GND Ground 1 2 CML-I Tx2n Transmitter Input Data Inverted 3 CML-I Tx2p Transmitter Non-Inverted Data Output 4 GND Ground 1 5 CML-I Tx4n Transmitter Inverted Data Output 6 CML-I Tx4p Transmitter Non-Inverted Data Output 7 Lemah 1 8 Modul ModSelL LVTTL-I Pilih 9 LVTTL-I ResetL Module Reset 10 VccRx +3.3V Power Supply Receiver 2 11 LVCMOS-I/O SCL 2-Wire Serial Interface Clock 12 LVCMOS-I/O SDA 2-Wire Serial Interface Data 13 GND Ground 1 14 CML- O Rx3p panrima Inverted Data Output 15 CML-O Rx3n Receiver Non-Inverted Data Output 16 GND Ground 1 17 CML-O Rx1p Receiver Inverted Data Output 18 CML-O Rx1n Receiver Non-Inverted Data Output 19 GND Ground 1 20 GND Ground 1 21 CML-O Receiver Rx2n Output Data Inverted CML-O Rx2n -O Rx2p Receiver Non-Inverted Data Output 23 GND Ground 1 24 CML-O Rx4n Receiver Inverted Data Output 25 CML-O Rx4p Receiver Non-Inverted Data Output 26 GND Ground 1 27 LVTTL-O ModPrsL LVT Interrupted Module 28 LVTTL-O ModPrsL Interrupt 28 Inverted 28 +3.3V Power Supply Transmitter 2 30 Vcc1 +3.3V Power Supply 2 31 LVTTL-I LPMode Low Power Mode 32 GND Ground 1 33 CML-I Tx3p Transmitter Inverted Data Output 34 CML-I Tx3n Transmitter Non-Inverted GND Data Output 35 1 36 Pemancar CML-I Tx1p Output Data Inverted 37 CML-I Tx1n Transmitter Output Data Non-Inverted 38 GND Ground 1 Cathetan: GND minangka simbol kanggo siji lan sumber (daya) umum kanggo modul QSFP, Kabeh umum ing modul QSFP lan kabeh voltase modul dirujuk menyang potensial iki digunakake nyatet. Sambungake iki langsung menyang sinyal Papan inang pesawat lemah umum. Output laser dipatèni ing TDIS>2.0V utawa mbukak, aktif ing TDIS
Inquiry
Rincian























